JunosOperating system · Juniper

CVE-2022-22202

MEDIUM · 6.5 CVSS v3.1 Published 2022-07-20
Fix available
A fix is available. Upgrade to 19.1 or later.
See remediation →
70/100
Remediation priority · Elevated
Public exploit No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An Improper Handling of Exceptional Conditions vulnerability on specific PTX Series devices, including the PTX1000, PTX3000 (NextGen), PTX5000, PTX10002-60C, PTX10008, and PTX10016 Series, in Juniper Networks Junos OS allows an unauthenticated MPLS-based attacker to cause a Denial of Service (DoS) by triggering the dcpfe process to crash and FPC to restart. On affected PTX Series devices, processing specific MPLS packets received on an interface with multiple units configured may cause FPC to restart unexpectedly. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects PTX Series devices utilizing specific FPCs found on PTX1000, PTX3000 (NextGen), PTX5000, PTX10002-60C, PTX10008, and PTX10016 Series devices, only if multiple units are configured on the ingress interface, and at least one unit has 'family mpls' *not* configured. See the configuration sample below for more information. No other platforms are affected by this vulnerability. This issue affects: Juniper Networks Junos OS on PTX Series: All versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R3-S6; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S2; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2; 22.1 versions prior to 22.1R2.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis

A detailed technical summary for this CVE is being prepared.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
JunosOperating system
Affected:< 19.1= 19.1= 19.2= 19.3= 19.4= 20.1= 20.2= 20.3= 20.4= 21.1= 21.2= 21.3

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 19.1 or later
Fixed in 19.1
Recommended fix High confidence

Upgrade to Junos OS 19.1R3-S9 or later (19.2R3-S6, 19.3R3-S6, 19.4R3-S8, 20.1R3-S4, 20.2R3-S5, 20.3R3-S4, 20.4R3-S4, 21.1R3-S2, 21.2R3-S1, 21.3R3, 21.4R2, or 22.1R2 or later)

  1. 1. Identify the current Junos OS version on the affected PTX Series device using 'show version'
  2. 2. Determine if the device meets the vulnerability conditions: multiple units configured on an ingress interface, with at least one unit lacking 'family mpls' configuration
  3. 3. If vulnerable, plan for an upgrade to a fixed release
  4. 4. Backup the current configuration using 'request system configuration backup' or 'file copy /config/juniper.conf.gz'
  5. 5. Schedule a maintenance window for the upgrade
  6. 6. Upgrade Junos OS to one of the fixed versions: 19.1R3-S9, 19.2R3-S6, 19.3R3-S6, 19.4R3-S8, 20.1R3-S4, 20.2R3-S5, 20.3R3-S4, 20.4R3-S4, 21.1R3-S2, 21.2R3-S1, 21.3R3, 21.4R2, or 22.1R2 or later
  7. 7. After upgrade, verify the FPC is online with 'show chassis fpc'
  8. 8. Confirm the dcpfe process is running with 'show system processes'
Caveat Review Juniper release notes for any behavior changes between current and target version; ensure configuration compatibility before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

We can perform the upgrade in your staging environment and verify nothing breaks — typical engagement from $1,600. Get the upgrade done

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2022-22202 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2022-22202 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data