CVE-2022-25789
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA maliciously crafted DWF, 3DS and DWFX files in Autodesk AutoCAD 2022, 2021, 2020, 2019 can be used to trigger use-after-free vulnerability. Exploitation of this vulnerability may lead to code execution.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA use-after-free vulnerability exists in Autodesk AutoCAD 2019-2022 when parsing maliciously crafted DWF, 3DS, and DWFX files. The vulnerability occurs when memory is freed but still referenced, allowing an attacker to manipulate memory and achieve code execution.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2022, < 2022.2.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2>= 2019, < 2019.1.4>= 2020, < 2020.1.5>= 2021, < 2021.1.2>= 2022, < 2022.1.2CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify installed Autodesk productCheck Windows registry under HKLM\SOFTWARE\Autodesk\AutoCAD or look in Add/Remove Programs for Autodesk product names such as AutoCAD, AutoCAD Architecture, AutoCAD Electrical, AutoCAD LT, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, or Advance SteelAffected if Any of these Autodesk products are installed
-
Determine installed version and build numberOpen AutoCAD and type VER or ABOUT at the command prompt, or check registry key HKLM\SOFTWARE\Autodesk\AutoCAD\<version>\Setup\InstallPath for the installed version stringAffected if Version matches the affected ranges: 2019.x before 2019.1.4, 2020.x before 2020.1.5, 2021.x before 2021.1.2, or 2022.x before 2022.1.2 (or before 2022.2.2 for plain AutoCAD)
-
Verify DWF/DWFX/3DS import capabilityCheck if the application has the standard file open dialog and verify that DWF, 3DS, and DWFX extensions are listed as supported import formats in the application options or by attempting to open a sample fileAffected if The application can import or open DWF, 3DS, or DWFX files, making the parsing code reachable
The environment is affected if any Autodesk product from the list is installed with a version falling between 2019 and the fixed releases (2019.1.4, 2020.1.5, 2021.1.2, or 2022.1.2/2022.2.2 depending on product and year), and the application supports parsing DWF/3DS/DWFX file formats.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped2019.1.42020.1.52021.1.2
Apply vendor patches when available. Until then, restrict opening untrusted DWF/3DS/DWFX files and educate users about opening files from unknown sources.
Upgrade to the latest version within your product year: 2019.1.4+, 2020.1.5+, 2021.1.2+, or 2022.1.2+ depending on your baseline release
- 1. Identify the exact installed version of your Autodesk product (Advance Steel, AutoCAD, AutoCAD Architecture, AutoCAD Electrical, AutoCAD LT, AutoCAD Map 3D, AutoCAD Mechanical, or AutoCAD MEP) from the Help > About menu.
- 2. Close any running instances of the Autodesk application.
- 3. If your version is 2019.x and less than 2019.1.4, upgrade to version 2019.1.4 or later.
- 4. If your version is 2020.x and less than 2020.1.5, upgrade to version 2020.1.5 or later.
- 5. If your version is 2021.x and less than 2021.1.2, upgrade to version 2021.1.2 or later.
- 6. If your version is 2022.x and less than 2022.1.2, upgrade to version 2022.1.2 or later.
- 7. Download the appropriate update from the Autodesk Account portal or the official Autodesk support website (www.autodesk.com).
- 8. Install the update following the on-screen instructions.
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation6.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,760.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2022-25789 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2022-25789 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data