CVE-2022-26388
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceMultiple ELI electrocardiograph devices contain a hard-coded password embedded in firmware that can be used to authenticate to the device, potentially allowing unauthorized access to patient data or device controls.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Physical
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- Low
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify ELI electrocardiograph devices on your networkReview network scan results, device inventory, or conduct an active scan for devices matching ELI product names (ELI 380, ELI 280, ELI 250c, ELI 150c). Check manufacturer documentation or consult your biomedical engineering records.Affected if ELI devices are present on the network
-
Determine firmware version of each ELI deviceAccess the device admin interface through its web UI or connect to the device service port. Navigate to the System Information or About section to retrieve the firmware version string.Affected if Firmware version is below 2.6.1 for ELI 380, below 2.3.2 for ELI 280 series, below 2.1.3 for ELI 250c, or below 2.2.1 for ELI 150c
-
Verify if default credentials are still in useAttempt to log into the device admin interface using the default credentials documented in the device setup guide, or check if credentials have been changed from manufacturer defaults.Affected if Device still accepts factory default credentials or uses the hardcoded credential embedded in the firmware
-
Confirm device network exposureReview firewall rules and network segmentation to determine if the ELI device is accessible from untrusted network segments or the internet.Affected if Device is directly accessible from outside the trusted medical device network zone
Your environment is affected if you have any ELI 380, ELI 280, ELI 250c, or ELI 150c electrocardiograph devices running firmware versions prior to the patched releases AND the device either uses default credentials or is exposed to untrusted networks.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpdate to patched firmware versions (2.6.1 or later for ELI 380, 2.3.2 or later for ELI 280 series, 2.1.3 or later for ELI 250c, 2.2.1 or later for ELI 150c); if patching unavailable, isolate devices on a restricted network and change default credentials.
Firmware versions higher than those listed (2.6.0 for ELI 380, 2.3.1 for ELI 280 series, 2.1.2 for ELI 250c, 2.2.0 for ELI 150c) - contact vendor for exact fixed releases
- Contact Hillrom (now Baxter) technical support to request the firmware update that addresses the hard-coded password vulnerability
- Verify the current firmware version on each affected ELI device before applying the update
- Apply the vendor-supplied firmware update to each affected electrocardiograph model: ELI 380 (to version above 2.6.0), ELI 280/BUR280/MLBUR 280 (to version above 2.3.1), ELI 250c/BUR 250c (to version above 2.1.2), ELI 150c/BUR 150c/MLBUR 150c (to version above 2.2.0)
- After updating, change any default credentials used by the device to strong, unique passwords
- Implement network segmentation to isolate medical devices from general network infrastructure
- Review CISA ICS Advisory ICSA-22-161-01 for additional mitigation recommendations
- Document the update process and verify device functionality post-update
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2022-26388 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2022-26388 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data