Data Center ManagerApplication · Intel

CVE-2022-33942

HIGH · 8.8 CVSS v3.1 Published 2022-11-11
Fix available
A fix is available. Upgrade to 5.0 or later.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Protection mechanism failure in the Intel(R) DCM software before version 5.0 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Intel DCM software before version 5.0 contains a protection mechanism failure that allows an unauthenticated attacker with adjacent network access to potentially escalate privileges. This is a local privilege escalation vulnerability exploitable by adjacent attackers who do not need valid credentials.

MitigationUpgrade Intel DCM software to version 5.0 or later to remediate this vulnerability. If immediate upgrading is not possible, restrict network access to the DCM management interface to trusted sources only.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Data Center ManagerApplication
Affected:< 5.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify Intel DCM is installed
    Check for Intel Data Center Manager software on the system using system inventory tools or installed programs list
    Affected if Intel DCM software is present on the system
  2. Determine installed DCM version
    Locate and read the Intel DCM version information through the software itself, installation directory, or system registry
    Affected if The installed version is any version prior to 5.0 (e.g., 4.x, 3.x, etc.)
  3. Confirm DCM service is running
    Check if the Intel DCM service or daemon is currently active on the system
    Affected if The DCM service is running and the version is below 5.0
  4. Assess network exposure of DCM interface
    Review network configuration to determine if the DCM management interface is accessible from adjacent network segments
    Affected if The management interface is reachable from untrusted adjacent network locations while running a vulnerable version

A system is affected if Intel Data Center Manager software version below 5.0 is installed and its management interface is network-accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 5.0 or later
Fixed in 5.0
Interim mitigation

Upgrade Intel DCM software to version 5.0 or later to remediate this vulnerability. If immediate upgrading is not possible, restrict network access to the DCM management interface to trusted sources only.

Recommended fix High confidence

Version 5.0

  1. Identify the current version of Intel Data Center Manager (DCM) installed in your environment
  2. Consult Intel's official documentation or support portal for upgrade instructions to version 5.0
  3. Plan and schedule a maintenance window for the upgrade process
  4. Back up all existing DCM configuration data and databases before proceeding
  5. Follow the documented upgrade procedure to migrate from the current version to version 5.0
  6. Verify the upgrade was successful by checking the DCM version and confirming all services are running
  7. Test that normal DCM operations and authentication mechanisms are functioning properly

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Data Center Manager Scoped from the published advisory
  • Consultation3.0 h
  • Implementation4.0 h
  • Testing6.0 h
  • Review / QA3.0 h
16.0 hours of engineering $2,760
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,416.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2022-33942 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2022-33942 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data