Sinec InsApplication · Siemens

CVE-2022-45093

HIGH · 8.8 CVSS v3.1 Published 2023-01-10
Fix available
A fix is available. Upgrade to 1.0 or later.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

An authenticated file read/write vulnerability in SINEC INS allows attackers with credentials to both the Web Based Management (443/tcp) and SFTP server (22/tcp) to read and write arbitrary files to the device's file system. This file operation primitive can be leveraged for remote code execution by writing malicious content to web-accessible directories or modifying system configurations.

MitigationUpgrade SINEC INS to version V1.0 SP2 Update 1 or later. Until then, restrict network access to ports 443 and 22 to trusted personnel only, and enforce strong, unique credentials for both management interfaces.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Sinec InsApplication
Affected:< 1.0= 1.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify SINEC INS installation and version
    Locate SINEC INS in your system inventory or installed software list, and note the exact version number installed. Compare this version against the affected range: versions < 1.0 and = 1.0 are vulnerable.
    Affected if The installed version is 1.0 or any version below 1.0.
  2. Verify Web Based Management port 443 is accessible
    Check if TCP port 443 is open and accepting connections on the device hosting SINEC INS. Use a network scan or check firewall rules to confirm exposure.
    Affected if Port 443 is reachable from an untrusted network and SINEC INS version is 1.0 or below.
  3. Verify SFTP server port 22 is accessible
    Check if TCP port 22 is open and accepting connections on the device hosting SINEC INS. Use a network scan or check firewall rules to confirm exposure.
    Affected if Port 22 is reachable from an untrusted network and SINEC INS version is 1.0 or below.
  4. Confirm authentication credentials exist for affected services
    Determine whether valid credentials exist for the SINEC INS Web Based Management interface (port 443) and/or the SFTP server (port 22). This vulnerability requires valid authentication to exploit.
    Affected if Valid credentials are configured for either the WBM or SFTP service, and the SINEC INS version is 1.0 or below.

You are affected if SINEC INS version 1.0 or below is installed, the Web Based Management (443/tcp) or SFTP (22/tcp) interfaces are accessible, and valid credentials exist for these services.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 1.0 or later
Fixed in 1.0
Interim mitigation

Upgrade SINEC INS to version V1.0 SP2 Update 1 or later. Until then, restrict network access to ports 443 and 22 to trusted personnel only, and enforce strong, unique credentials for both management interfaces.

Recommended fix High confidence

V1.0 SP2 Update 1

  1. Obtain SINEC INS version V1.0 SP2 Update 1 (or later) from the official Siemens support portal
  2. Follow the standard SINEC INS upgrade procedure to apply the update
  3. Verify the upgrade was successful by checking the version number in the Web Based Management interface

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Sinec Ins Scoped from the published advisory
  • Consultation4.0 h
  • Implementation2.0 h
  • Testing6.0 h
  • Review / QA3.0 h
15.0 hours of engineering $2,600
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,160.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2022-45093 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2022-45093 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data