CVE-2023-1150
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedUncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe WAGO 750-3x/-8x series controllers contain a MODBUS server implementation vulnerable to uncontrolled resource consumption. Specially crafted MODBUS packets can exhaust server resources, causing denial of service. The vulnerability is exploitable remotely without authentication, allowing attackers to crash the MODBUS service.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< fw11< fw11< fw11< fw11< fw11< fw11< fw11< fw11CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the WAGO controller modelLocate the model number on the device label or check the device documentation/web interface. Look for model numbers: 750-363, 750-362, 750-364, 750-365, or 750-891.Affected if The model number matches one of these: 750-363, 750-362, 750-364, 750-365, or 750-891.
-
Determine the installed firmware versionAccess the WAGO controller web interface or use the WAGO Configuration Studio to read the firmware version. The version is typically displayed in the device info or system status page.Affected if The firmware version is shown as a version number lower than fw11, or the version cannot be confirmed as fw11 or higher.
-
Verify MODBUS server is enabledCheck the controller configuration settings. In the WAGO web interface, navigate to Services or Communication settings to confirm if the MODBUS server (MODBUS TCP) is enabled and running.Affected if MODBUS TCP server is enabled and listening on the network.
-
Check network exposure of MODBUS serviceReview network firewall rules and access control lists to determine if the MODBUS port (typically port 502) is accessible from untrusted networks or the internet.Affected if MODBUS port 502 is accessible from untrusted network segments or directly from the internet.
The device is affected if it is a WAGO 750-3x/750-8x series controller (models 750-362, 750-363, 750-364, 750-365, or 750-891) running firmware version below fw11, with MODBUS TCP server enabled and exposed on the network.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedApply vendor firmware updates when available. In the interim, implement network segmentation to isolate OT assets and restrict MODBUS traffic to authorized endpoints using firewalls or access control lists.
Firmware fw11 or later for WAGO 750-3x/-8x series controllers (750-362, 750-363, 750-364, 750-365, 750-891)
- 1. Identify the specific WAGO 750 series controller model (e.g., 750-363, 750-362, 750-891, etc.) in your environment from the affected product list.
- 2. Access the WAGO controller's web interface or use WAGO's programming software (e.g., e!COCKPIT or CODESYS) to check the current firmware version.
- 3. If firmware version is below fw11, download the latest firmware version fw11 or later from the official WAGO website or support portal.
- 4. Follow WAGO's standard firmware update procedure: typically via the web interface under 'Firmware Update' or using the programming tool's firmware update function.
- 5. Verify the firmware update was successful by checking the firmware version after the update.
- 6. Test that the MODBUS server is functioning properly after the update.
- 7. Implement network segmentation and firewall rules to limit MODBUS traffic to trusted sources as an additional mitigation measure while updating.
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-1150 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-1150 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data