Ecostruxure Control ExpertApplication · Schneider Electric

CVE-2023-1548

MEDIUM · 5.5 CVSS v3.1 Published 2023-04-18
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
57/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

This is a CWE-269 Improper Privilege Management vulnerability in EcoStruxure Control Expert's console server service. A local user can exploit improper privilege handling to cause a denial of service, likely through unauthorized access to privileged operations or service disruption.

MitigationApply vendor-provided patches for EcoStruxure Control Expert V15.1 and above. Review and restrict console server service permissions to ensure least-privilege principles. Contact Schneider Electric for specific patch availability and hardening guidance.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Ecostruxure Control ExpertApplication
Affected:>= 15.1

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if EcoStruxure Control Expert is installed
    Look for EcoStruxure Control Expert in installed programs or check for the installation directory typically under Program Files/Schneider Electric
    Affected if The software is present on the system
  2. Determine the installed version of EcoStruxure Control Expert
    Check the version information in the application's About dialog, installation logs, or registry entries under the software's installation path
    Affected if The installed version is 15.1 or higher
  3. Verify the console server service is present and running
    Open Services console (services.msc) and look for a service related to console server functionality, or check running processes for console server components
    Affected if The console server service or process is running on the system
  4. Check console server service configuration and permissions
    Open Services console, right-click the console server service, select Properties, and review the Log On tab to see under what account the service runs
    Affected if The service runs with elevated privileges or with an account that has excessive permissions

If EcoStruxure Control Expert version 15.1 or higher is installed with the console server service running, the environment may be affected by this improper privilege management vulnerability.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor-provided patches for EcoStruxure Control Expert V15.1 and above. Review and restrict console server service permissions to ensure least-privilege principles. Contact Schneider Electric for specific patch availability and hardening guidance.

Fix this in Ecostruxure Control Expert Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-1548 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-1548 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data