CVE-2023-22417
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA Missing Release of Memory after Effective Lifetime vulnerability in the Flow Processing Daemon (flowd) of Juniper Networks Junos OS allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). In an IPsec VPN environment, a memory leak will be seen if a DH or ECDH group is configured. Eventually the flowd process will crash and restart. This issue affects Juniper Networks Junos OS on SRX Series: All versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R2-S8, 19.4R3-S10; 20.2 versions prior to 20.2R3-S6; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S4; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R2.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA memory leak vulnerability exists in the Flow Processing Daemon (flowd) of Juniper Junos OS on SRX Series devices. When IPsec VPN is configured with DH or ECDH groups, memory is not properly released after effective lifetime, causing gradual memory exhaustion. Eventually the flowd process crashes and restarts, resulting in a denial of service. The attacker requires no authentication and only needs to send traffic through the affected IPsec VPN tunnel.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 19.3= 19.4= 20.2= 20.3= 20.4= 21.1= 21.2= 21.3= 21.4CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify device modelRun 'show chassis hardware' or 'show system information' to confirm the device is an SRX Series modelAffected if Device is not an SRX Series device (vulnerability only affects SRX Series)
-
Check Junos OS versionRun 'show version' and compare the installed version against affected ranges: 19.3, 19.4, 20.2, 20.3, 20.4, 21.1, 21.2, 21.3, 21.4Affected if Version matches one of the affected versions listed in the CVE
-
Verify IPsec VPN configuration existsRun 'show configuration security ipsec' to see if any IPsec VPN tunnels are configuredAffected if No IPsec VPN tunnels are configured (vulnerability requires IPsec VPN to be present)
-
Check for DH or ECDH groups in IPsec configRun 'show configuration security ipsec' and look for 'dh-group' or 'group' statements under IPsec proposal or policy configurationsAffected if DH (Diffie-Hellman) or ECDH groups are configured in IPsec VPN settings - this is the required condition for the memory leak
-
Monitor flowd memory usageRun 'show system processes extensive | match flowd' repeatedly over time to observe if memory usage steadily increasesAffected if flowd process shows continuously increasing memory consumption, which indicates the memory leak is active
Device is affected if it is an SRX Series running a listed Junos version with an IPsec VPN configuration that uses DH or ECDH groups, showing symptoms of increasing flowd memory usage.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedApply the appropriate Junos OS software update for your version (19.3R3-S7, 19.4R2-S8/19.4R3-S10, 20.2R3-S6, 20.3R3-S5, 20.4R3-S5, 21.1R3-S4, 21.2R3, 21.3R3, or 21.4R2 and later). As a workaround, avoid using DH or ECDH groups in IPsec VPN configurations if upgrading is not immediately feasible.
Upgrade to 19.3R3-S7 or later (19.3 branch), 19.4R3-S10/19.4R2-S8 or later (19.4 branch), 20.2R3-S6 or later (20.2 branch), or 20.3R3-S5 or later (20.3 branch)
- Identify the current Junos OS version on the SRX Series device using 'show version'
- Determine which version branch the device is currently running (19.3, 19.4, 20.2, or 20.3)
- Back up the current device configuration using 'request system configuration rescue save'
- Schedule a maintenance window for the upgrade
- Upgrade to a fixed version: for 19.3 branch upgrade to 19.3R3-S7 or later; for 19.4 branch upgrade to 19.4R3-S10 or later (or 19.4R2-S8); for 20.2 branch upgrade to 20.2R3-S6 or later; for 20.3 branch upgrade to 20.3R3-S5 or later
- After upgrade, monitor the flowd process memory usage using 'show system processes extensive | match flowd' to verify the memory leak is resolved
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation2.0 h
- Implementation4.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,088.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-22417 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-22417 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data