CVE-2023-24502
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedElectra Central AC unit – The unit opens an AP with an easily calculated password.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceElectra Central AC units open a WiFi Access Point with an easily calculated password, allowing nearby attackers to derive the password and gain unauthorized network access to the device.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= v4= v5= v7= v8CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelLocate the physical AC unit or its network registration and confirm it is an Electra Air Central AC UnitAffected if The device is an Electra Air Central AC Unit
-
Check the installed firmware versionAccess the unit's admin interface or check the device firmware information through its management software or physical labelAffected if The firmware version is v4, v5, v7, or v8
-
Determine if the WiFi Access Point feature is enabledInspect the unit's network settings or wireless configuration to see if the AP mode is activeAffected if The WiFi AP feature is turned on and broadcasting
-
Verify the AP password configurationCheck the wireless security settings of the device's AP to see if it uses a default or predictable password patternAffected if The AP uses a default or easily derivable password rather than a strong, unique one
A user is affected if they have an Electra Air Central AC Unit running firmware v4, v5, v7, or v8 with the WiFi AP feature enabled and a default or predictable password configured.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware patch when available; disable the AP feature if not needed; network segment the AC unit to limit exposure.
- Consultation2.0 h
- Implementation1.0 h
- Testing1.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,456.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-24502 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-24502 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data