CVE-2023-28389
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedIncorrect default permissions in some Intel(R) CSME installer software before version 2328.5.5.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe Intel CSME (Converged Security and Management Engine) installer software versions prior to 2328.5.5.0 shipped with incorrect default file system permissions. An authenticated local user could exploit these misconfigured permissions to gain elevated privileges on the system where the installer is run.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- High
- Privileges
- Low
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Locate Intel CSME installer software on the systemSearch program files directories and any Intel installation folders for files containing 'CSME' or 'Converged Security' in the name, or look for Intel installer packages related to CSMEAffected if The installer software is present on the system and its version is below 2328.5.5.0
-
Determine the installed version of the Intel CSME installerRight-click the installer executable, select Properties, and view the Details tab to find the File Version or Product Version fieldAffected if The displayed version number is less than 2328.5.5.0 (for example, 2328.x.x.x versions below 2328.5.5.0, or any earlier major version)
-
Check Windows Installed Programs for CSME installer entryOpen Programs and Features (appwiz.cpl) or the Registry at HKLM\Software\Microsoft\Windows\CurrentVersion\Uninstall to look for installed Intel CSME-related software and note its versionAffected if An Intel CSME installer entry exists with a version string earlier than 2328.5.5.0
Your system is affected if the Intel CSME installer software version is present and is any version prior to 2328.5.5.0, as only version 2328.5.5.0 and later contain the corrected default file system permissions.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpgrade Intel CSME installer software to version 2328.5.5.0 or later to obtain the corrected default permissions.
- Consultation2.0 h
- Implementation4.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-28389 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-28389 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm