StationguardApplication · Omicronenergy

CVE-2023-28610

CRITICAL · 9.8 CVSS v3.1 Published 2023-03-23
Fix available
A fix is available. Upgrade to after 2.20 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The update process in OMICRON StationGuard and OMICRON StationScout before 2.21 can be exploited by providing a modified firmware update image. This allows a remote attacker to gain root access to the system.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The firmware update mechanism in OMICRON StationGuard and StationScout lacks proper validation of firmware images, allowing attackers to supply modified (malicious) firmware updates that bypass security checks and execute with root privileges.

MitigationUpdate affected devices to version 2.21 or later to obtain the patched firmware. If immediate updating is not feasible, restrict network access to the update interfaces and monitor for unauthorized firmware upload attempts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
StationguardApplication
Affected:<= 2.20
StationscoutApplication
Affected:<= 2.20

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed software version
    Access the device management interface or use the command line tool provided by OMICRON to query the installed version of StationGuard or StationScout. This is typically found in the device information or system status section of the web UI or via CLI command such as 'version' or 'show system-info'.
    Affected if The installed version is 2.20 or lower (any version <= 2.20 indicates the vulnerable version)
  2. Verify firmware update service status
    Check if the firmware update mechanism or service is enabled on the device. This can be done by examining the device configuration or service status through the management interface or by reviewing configuration files related to firmware updates.
    Affected if The firmware update service is enabled and accessible, making the device susceptible to malicious firmware uploads
  3. Assess network exposure of update interfaces
    Review network configuration to determine if the firmware update interfaces are exposed to untrusted networks. Check firewall rules, access control lists, and network segmentation settings around the device.
    Affected if The firmware update interfaces are reachable from network segments that are not fully trusted or are exposed to external networks

A user is affected if they are running StationGuard or StationScout version 2.20 or earlier AND have the firmware update mechanism exposed or enabled on their network.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to a release after 2.20
Interim mitigation

Update affected devices to version 2.21 or later to obtain the patched firmware. If immediate updating is not feasible, restrict network access to the update interfaces and monitor for unauthorized firmware upload attempts.

Recommended fix High confidence

2.21 or later

  1. Upgrade OMICRON StationGuard to version 2.21 or later
  2. Upgrade OMICRON StationScout to version 2.21 or later
  3. After upgrading, verify the firmware update signature verification is working correctly by reviewing system logs

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Stationguard Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA1.0 h
10.0 hours of engineering $1,750
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,800.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-28610 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-28610 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data