Icr890 4 FirmwareOperating system · Sick

CVE-2023-35697

HIGH · 7.5 CVSS v3.1 Published 2023-07-10
Fix available
A fix is available. Upgrade to 2.5.0 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4 could allow a remote attacker to brute-force user credentials.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The SICK ICR890-4 device contains an improper restriction of excessive authentication attempts vulnerability. This allows a remote attacker to perform brute-force attacks on user credentials by making repeated authentication attempts without being locked out or rate-limited.

MitigationImplement account lockout policies after a configurable number of failed login attempts, add rate limiting to authentication endpoints, and consider network segmentation to reduce attack surface exposure while awaiting vendor firmware updates.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Icr890 4 FirmwareOperating system
Affected:< 2.5.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Access the device web interface or check the device label/documentation to confirm the model is ICR890-4
    Affected if The device is not a SICK ICR890-4 model
  2. Check the installed firmware version
    Log into the device admin interface and navigate to System > Firmware or Status page to view the current firmware version. Compare against the affected range of < 2.5.0
    Affected if The firmware version displayed is below 2.5.0 (e.g., 2.4.x, 2.3.x, etc.)
  3. Verify remote authentication interface accessibility
    Check if the device HTTP/HTTPS management interface is exposed to untrusted networks by reviewing firewall rules or network configuration
    Affected if The device authentication interface is reachable from external or untrusted networks without network segmentation
  4. Confirm authentication rate limiting is not enforced
    Attempt multiple failed authentication attempts (with a test account if available) or review device security settings for account lockout or rate limiting configuration
    Affected if The device allows unlimited authentication attempts without triggering a lockout or delay

You are affected if you have a SICK ICR890-4 device running firmware version below 2.5.0 with its authentication interface remotely accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2.5.0 or later
Fixed in 2.5.0
Interim mitigation

Implement account lockout policies after a configurable number of failed login attempts, add rate limiting to authentication endpoints, and consider network segmentation to reduce attack surface exposure while awaiting vendor firmware updates.

Recommended fix Moderate confidence

Firmware 2.5.0 or later

  1. Obtain the SICK ICR890-4 firmware version 2.5.0 or later from the official SICK support website (sick.com)
  2. Access the device management interface for the ICR890-4
  3. Upload and install the firmware version 2.5.0 or later following the manufacturer's firmware upgrade instructions
  4. Verify the firmware was successfully installed by checking the device version information
  5. Confirm the brute-force protection is now properly functioning
Caveat Review SICK release notes for any configuration or operational changes between your current version and 2.5.0

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Icr890 4 Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA2.0 h
20.0 hours of engineering $3,500
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-35697 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-35697 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data