CVE-2023-38570
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAccess of memory location after end of buffer for some Intel Unison software may allow an authenticated user to potentially enable escalation of privilege via local access.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA buffer access vulnerability in Intel Unison software allows an authenticated local attacker to read memory beyond buffer boundaries, potentially achieving privilege escalation. The flaw stems from improper bounds checking when accessing memory locations.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 20.14.5683.0< 20.14.4244< 20.14.2.3053CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check if Intel Unison is installedOn Windows: Open Programs and Features or check C:\Program Files\Intel\Unison. On macOS: Check /Applications for Intel Unison.app. On Linux: Check /usr/bin/unison or /opt/intel/unison.Affected if Intel Unison software is not present on the system, the vulnerability does not apply.
-
Determine installed Intel Unison versionOn Windows: Right-click the Unison application in Programs and Features, select Properties, and view the Version field. Alternatively, run 'wmic product get name,version' and filter for Intel Unison. On macOS: Right-click Intel Unison.app, select Get Info, and check the Version field.Affected if The installed version is lower than 20.14.5683.0, 20.14.4244, or 20.14.2.3053 (any version below these thresholds is affected).
-
Verify the Unison service or process is runningOn Windows: Open Task Manager or run 'Get-Service | Where-Object {$_.Name -like "*Unison*"}' in PowerShell. On macOS/Linux: Run 'ps aux | grep -i unison' in terminal.Affected if If Intel Unison is installed but not running, the immediate attack surface is reduced, though the vulnerable binary still exists on the system.
-
Review local user accounts with Unison accessCheck which local users have permissions to run or access Intel Unison. On Windows: Use 'icacls' on the Unison installation directory or check Local Users and Groups (lusrmgr.msc). On Linux: Check file permissions with 'ls -la' on the Unison binary directory.Affected if If untrusted or unauthorized local user accounts exist on the system, they could potentially exploit this vulnerability to read memory beyond buffer boundaries.
A system is affected if Intel Unison software is installed with a version lower than 20.14.5683.0 (or 20.14.4244 or 20.14.2.3053), especially when untrusted local users have access to run the software.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped20.14.2.305320.14.424420.14.5683.0
Apply the Intel-provided security update for Unison software to patch the buffer access vulnerability. Verify no unauthorized local accounts exist and follow least-privilege principles for local user access.
Intel Unison version 20.14.5683.0 or later (or 20.14.4244 or later, or 20.14.2.3053 or later depending on your release track)
- Navigate to the official Intel support or download page for Intel Unison software
- Locate the Intel Unison software download section
- Download version 20.14.5683.0 or later
- Ensure you have administrative privileges on the target system
- Close any running instances of Intel Unison
- Install the updated version following the standard installation process
- Restart the system if prompted or if the service does not restart automatically
- Verify the installed version matches or exceeds 20.14.5683.0
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation3.0 h
- Implementation2.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,832.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2023-38570 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2023-38570 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data