HcellApplication · Hancom

CVE-2023-40250

HIGH · 8.8 CVSS v3.1 Published 2024-01-12
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
95/100
Remediation priority · Urgent
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Hancom HCell on Windows allows Overflow Buffers.This issue affects HCell: 12.0.0.893.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Buffer overflow vulnerability in Hancom HCell spreadsheet software version 12.0.0.893 on Windows. The vulnerability results from unsafe buffer copy operations that do not validate input size, allowing attackers to overflow buffers and potentially execute arbitrary code.

MitigationApply vendor patch when available; until then, restrict usage of untrusted HCell files and monitor for anomalous behavior. Consider application whitelisting and network segmentation as compensating controls.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
HcellApplication
Affected:= 12.0.0.893

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate Hancom HCell installation
    Check Program Files or Program Files (x86) folders for 'Hancom HCell' directory, or search for 'HCell.exe' on the system
    Affected if The software is installed on the Windows system
  2. Check installed HCell version
    Right-click HCell.exe, select Properties, then view the Details tab for Product Version; alternatively, open HCell and go to Help > About Hancom HCell
    Affected if The version displayed is exactly 12.0.0.893
  3. Verify version via Windows Registry
    Open Registry Editor and navigate to HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall or HKLM\SOFTWARE\Hancom\HCell, looking for DisplayVersion or Version entries
    Affected if Registry shows version 12.0.0.893 for Hancom HCell

You are affected if Hancom HCell version 12.0.0.893 is installed and running on your Windows system; no other versions are listed as vulnerable.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor patch when available; until then, restrict usage of untrusted HCell files and monitor for anomalous behavior. Consider application whitelisting and network segmentation as compensating controls.

Fix this in Hcell Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2023-40250 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2023-40250 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data