CVE-2024-11166
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedFor TCAS II systems using transponders compliant with MOPS earlier than RTCA DO-181F, an attacker can impersonate a ground station and issue a Comm-A Identity Request. This action can set the Sensitivity Level Control (SLC) to the lowest setting and disable the Resolution Advisory (RA), leading to a denial-of-service condition.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceTCAS II systems using transponders compliant with MOPS versions earlier than RTCA DO-181F are vulnerable to a denial-of-service attack. An attacker impersonating a ground station can send a malicious Comm-A Identity Request that sets the Sensitivity Level Control (SLC) to its lowest setting and disables the Resolution Advisory (RA) function, preventing the system from providing collision avoidance alerts.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify transponder model and firmware versionLocate the transponder equipment label or check system documentation for the transponder model number and installed firmware version. Consult the manufacturer's documentation to determine the MOPS compliance level.Affected if The transponder firmware version corresponds to MOPS versions earlier than RTCA DO-181F compliance.
-
Determine RTCA DO standard complianceReview the transponder's compliance documentation, certification documents (such as ETSO authorization), or contact the manufacturer to verify which RTCA DO standard (e.g., DO-181E, DO-181F) the transponder is designed to meet.Affected if The transponder is documented to comply with standards earlier than RTCA DO-181F.
-
Check for SLC modification capabilityReview transponder configuration settings or system logs for any Sensitivity Level Control (SLC) parameters. Examine whether the transponder accepts Comm-A messages that can modify SLC settings without authentication.Affected if The transponder accepts and processes Comm-A Identity Request messages that can modify SLC settings, and lacks protections against malicious SLC manipulation.
-
Verify RA function statusCheck TCAS II system status indicators or logs for Resolution Advisory (RA) functionality. Confirm whether RA can be disabled via external Comm-A commands.Affected if The RA function can be disabled or the SLC can be set to its lowest setting through received Comm-A messages.
Your environment is affected if your TCAS II transponder complies with MOPS versions earlier than RTCA DO-181F and accepts unprotected Comm-A Identity Request messages that can modify SLC settings or disable RA functionality.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpgrade transponder firmware or replace transponders to comply with RTCA DO-181F or later, which includes protections against malicious SLC manipulation via Comm-A messages.
- Consultation40.0 h
- Implementation120.0 h
- Testing60.0 h
- Review / QA40.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $73,280.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-11166 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-11166 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data