CWE-656Weakness · CWE-656

CVE-2024-12297

CRITICAL · 9.2 CVSS v4.0 Published 2025-01-15
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Moxa Ethernet switch contains an authentication bypass vulnerability stemming from flawed authorization mechanisms in both client-side and back-end server verification. Attackers can exploit this through brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially achieving full device compromise.

MitigationImplement network segmentation to isolate affected devices, restrict management interface access to trusted IP ranges, and contact Moxa for available firmware patches or mitigations.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
Authentication
X
User interaction
None
Scope
X

CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Moxa Ethernet switch in your environment
    Determine if any network devices are Moxa brand Ethernet switches by checking device MAC addresses (Moxa OUI patterns), SNMP sysDescr values, or web interface banner/header information
    Affected if The device is confirmed to be a Moxa Ethernet switch with web-based management interface
  2. Check management interface exposure
    Review network firewall rules, ACLs, and border router configurations to determine if the device web management interface (HTTP/HTTPS ports 80/443 or custom ports) is accessible from untrusted networks or the internet
    Affected if Management interface is reachable from untrusted or public network segments without IP restriction
  3. Verify authentication mechanism configuration
    Access the device web interface and examine authentication settings, session management configuration, or security settings to determine if MD5 hashing is used for password storage or transmission
    Affected if Device uses MD5 hashing for authentication credentials or allows weak credential policies susceptible to brute-force
  4. Review authentication logs for attack indicators
    Examine device system logs, security logs, or authentication event logs for repeated failed login attempts from single source IPs, unusual timing patterns, or hash manipulation attempts
    Affected if Logs show evidence of brute-force attempts, repeated authentication failures, or anomalous authentication patterns
  5. Confirm client-side verification is in use
    Access the device web interface and use browser developer tools to inspect if authentication decisions are enforced client-side (JavaScript checks, hidden fields, cookie-based roles) versus server-side validation
    Affected if Authentication checks rely on client-side validation that can be bypassed or manipulated in the browser

Your environment is affected if you have a Moxa Ethernet switch with web management interface accessible from untrusted networks and using MD5-based or client-side authentication mechanisms.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement network segmentation to isolate affected devices, restrict management interface access to trusted IP ranges, and contact Moxa for available firmware patches or mitigations.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation12.0 h
  • Testing6.0 h
  • Review / QA3.0 h
25.0 hours of engineering $4,400
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,040.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-12297 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-12297 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm