CVE-2024-12740
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedVision-related software from NI used a third-party library for image processing that exposes several vulnerabilities. These vulnerabilities may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted file.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceNI Vision software includes a third-party image processing library containing multiple vulnerabilities that can be exploited by convincing a user to open a specially crafted image file, leading to arbitrary code execution with the privileges of the running application.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify NI Vision software installationCheck for NI Vision software in the system. Common locations: Windows - Program Files/National Instruments/Vision or registry keys under HKEY_LOCAL_MACHINE\SOFTWARE\National Instruments\Vision. Linux/Mac - check /Applications/NI or /usr/local/ni/vision directories.Affected if NI Vision software is found on the system
-
Determine NI Vision versionCheck the version of the installed NI Vision software. On Windows, right-click the NI Vision executable and select Properties > Details, or use the NI MAX utility to view installed software versions. On Linux, run 'nipkg list' or check /usr/local/ni/vision/version.txt.Affected if The installed version cannot be determined or falls within an affected version range (compare against vendor advisories for specific version numbers)
-
Identify the third-party image library versionLocate the third-party image processing library bundled with NI Vision. Common library files include libjpeg, libtiff, or similar. Check the DLL/SO file properties or use a tool like 'strings' to find version strings within the library binary.Affected if The third-party library version is older than the patched version released by NI (refer to vendor security advisory for exact version numbers)
-
Verify image file processing is enabledConfirm that NI Vision's image acquisition and processing features are available. Check if the Vision Acquisition Express or other Vision VIs can load and process image files. Review NI MAX to see if Vision hardware and software modules are enabled.Affected if NI Vision image processing functionality is present and operational on the system
A system is affected if NI Vision software is installed and the installed version or its bundled third-party image library is older than the patched version referenced in the vendor security advisory.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUsers should not open image files from untrusted sources. Organizations should monitor for vendor patches to the third-party library and apply updates once available, while verifying vision processing functionality after patching.
- Consultation4.0 h
- Implementation8.0 h
- Testing12.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,616.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-12740 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-12740 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data