CVE-2024-21603
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn Improper Check for Unusual or Exceptional Conditions vulnerability in the kernel of Juniper Network Junos OS on MX Series allows a network based attacker with low privileges to cause a denial of service. If a scaled configuration for Source class usage (SCU) / destination class usage (DCU) (more than 10 route classes) is present and the SCU/DCU statistics are gathered by executing specific SNMP requests or CLI commands, a 'vmcore' for the RE kernel will be seen which leads to a device restart. Continued exploitation of this issue will lead to a sustained DoS. This issue only affects MX Series devices with MPC10, MPC11 or LC9600, and MX304. No other MX Series devices are affected. This issue affects Juniper Networks Junos OS: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S6; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3; * 22.1 versions earlier than 22.1R3; * 22.2 versions earlier than 22.2R2; * 22.3 versions earlier than 22.3R2.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceImproper check for unusual conditions in Junos OS kernel on MX Series allows low-privileged network attacker to trigger RE kernel vmcore and device restart when scaled SCU/DCU configuration (>10 route classes) is present and specific SNMP requests or CLI commands trigger statistics gathering. Only affects MPC10, MPC11, LC9600, and MX304 hardware.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 20.4= 21.2= 21.3= 21.4= 22.1= 22.2= 22.3CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify hardware modelRun 'show chassis hardware' or 'show hardware' to confirm the device is an MX Series and identify the specific line card or hardware: MPC10, MPC11, LC9600, or MX304.Affected if Hardware is MX Series with MPC10, MPC11, LC9600, or MX304 line cards.
-
Check Junos OS versionRun 'show version' to obtain the installed Junos OS version.Affected if Version is 20.4, 21.2, 21.3, 21.4, 22.1, 22.2, or 22.3.
-
Verify SCU/DCU configurationRun 'show configuration | match "source-class|dest-class"' and count the number of unique route classes configured. Look for SCU (Source Class Usage) and DCU (Destination Class Usage) configurations.Affected if Scaled SCU/DCU configuration exists with more than 10 route classes defined.
-
Check SNMP configurationRun 'show configuration snmp' to see if SNMP is enabled and what communities or views are configured.Affected if SNMP is enabled and accessible to low-privileged network attackers.
-
Inspect for recent vmcore eventsRun 'show system core-dumps' or check /var/crash/ for recent vmcore files. Run 'show system reboot history' to look for unexpected restarts.Affected if Recent vmcore dumps or unexplained device restarts are present on the system.
The device is affected if it is an MX Series with MPC10/MPC11/LC9600/MX304 hardware, runs an affected Junos version (20.4, 21.2-22.3), has scaled SCU/DCU configuration with >10 route classes, and has exposed SNMP access or CLI permissions that could trigger the statistics gathering that causes the RE kernel vmcore and restart.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedApply Junos OS updates per version matrix; for affected devices with scaled SCU/DCU config, consider restricting SNMP access and CLI permissions until patch deployment.
Upgrade to 20.4R3-S9 / 21.2R3-S6 / 21.3R3-S5 / 21.4R3 / 22.1R3 / 22.2R2 / 22.3R2 or later (choose based on current version branch)
- 1. Identify the current Junos OS version on the MX Series device using 'show version' command
- 2. Determine the appropriate upgrade path based on current version (20.4 -> 20.4R3-S9, 21.2 -> 21.2R3-S6, 21.3 -> 21.3R3-S5, 21.4 -> 21.4R3, 22.1 -> 22.1R3, 22.2 -> 22.2R2, 22.3 -> 22.3R2)
- 3. Verify the device hardware is MPC10, MPC11, LC9600, or MX304 as only these are affected
- 4. Confirm the device has SCU/DCU configuration with more than 10 route classes using 'show configuration | match class'
- 5. Download the appropriate fixed Junos OS release from Juniper support portal
- 6. Upload the image to the device and verify integrity using 'request system software validate <image>'
- 7. Install the upgrade using 'request system software add <image> reboot'
- 8. After reboot, verify the new version with 'show version'
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-21603 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-21603 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm