Lenels2 NetboxApplication · Honeywell

CVE-2024-2420

CRITICAL · 9.8 CVSS v3.1 Published 2024-05-30
Fix available
A fix is available. Upgrade to 5.6.2 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

LenelS2 NetBox access control and event monitoring system contains hardcoded credentials embedded in the software code or configuration that allow attackers to bypass normal authentication mechanisms. An unauthenticated remote attacker can exploit these credentials to gain administrative access to the access control system, potentially allowing physical access controlOverride, event monitoring manipulation, and network pivoting.

MitigationUpdate NetBox to a version beyond 5.6.1 when a patch is released by LenelS2. If immediate patching is not possible, restrict network exposure of the NetBox management interface to trusted networks and implement additional authentication layers such as VPN access or MFA.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Lenels2 NetboxApplication
Affected:< 5.6.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify NetBox version
    Log into the NetBox administrative interface and navigate to the About or System Information page, or check the version displayed on the login page. Alternatively, consult system documentation or release notes for the installed instance.
    Affected if The installed version is lower than 5.6.2 (for example, 5.6.1, 5.5.x, or earlier)
  2. Confirm management interface exposure
    Review network firewall rules and access control lists to determine whether the NetBox web management interface (typically ports 80/443 or custom HTTP/HTTPS ports) is reachable from untrusted or external network segments.
    Affected if The management interface is accessible from untrusted networks or the internet without VPN or additional authentication barriers
  3. Audit administrative user accounts
    Within the NetBox administration panel, review the list of all administrative-level accounts for any unfamiliar or unauthorized users that may indicate exploitation using the hardcoded credentials.
    Affected if Unexpected administrative accounts exist that were not created by your organization
  4. Check for unauthorized configuration changes
    Review system logs, event logs, and audit trails for administrative actions performed at unexpected times, from unexpected IP addresses, or involving changes to access control rules, door schedules, or system settings that you did not initiate.
    Affected if Administrative actions appear in logs that were not performed by legitimate administrators

You are affected if your NetBox version is below 5.6.2 AND the management interface is network-accessible to untrusted parties, as this combination enables unauthenticated attackers to exploit the hardcoded credentials for administrative access.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 5.6.2 or later
Fixed in 5.6.2
Interim mitigation

Update NetBox to a version beyond 5.6.1 when a patch is released by LenelS2. If immediate patching is not possible, restrict network exposure of the NetBox management interface to trusted networks and implement additional authentication layers such as VPN access or MFA.

Recommended fix Moderate confidence

LenelS2 NetBox version 5.6.2

  1. 1. Review the official LenelS2 NetBox upgrade documentation before proceeding
  2. 2. Create a complete backup of the current NetBox configuration and database
  3. 3. Download LenelS2 NetBox version 5.6.2 from the official LenelS2 or Carrier support portal
  4. 4. Apply the upgrade following the vendor's documented upgrade procedure for NetBox
  5. 5. After upgrade, verify that the hardcoded credentials vulnerability has been addressed by attempting to authenticate with the previously known hardcoded credentials (they should no longer work)
  6. 6. Confirm normal system operation and access control functionality after the upgrade
Caveat Review vendor release notes for any configuration or integration changes between your current version and 5.6.2; test in non-production environment first

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Lenels2 Netbox Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-2420 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-2420 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data