Cp3 FirmwareOperating system · Tendacn

CVE-2024-24488

MEDIUM · 5.5 CVSS v3.1 Published 2024-02-07
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
57/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Tenda CP3V2.0 IP camera firmware V11.10.00.2311090948 contains a local information disclosure vulnerability where an attacker with local access can obtain sensitive information (likely plaintext passwords or credential data) through the password component. The CVSS 5.5 score indicates local access requirement with low attack complexity.

MitigationLimit physical and local network access to the device; contact Tenda for firmware updates; if no patch available, consider network segmentation and monitoring for unauthorized local access.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Cp3 FirmwareOperating system
Affected:= 11.10.00.2311090948

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify firmware version
    Access the device administration interface or check system information page to view the currently installed firmware version. On Tenda IP cameras, this is typically found in Settings > System > Version or through the web UI under System Info.
    Affected if The installed firmware version is exactly 11.10.00.2311090948
  2. Locate password configuration component
    Inspect the device for accessible password-related files, scripts, or configuration endpoints. This may include looking for password storage files, configuration backups, or API endpoints related to credential handling.
    Affected if Password configuration files or components are readable by unauthorized local users or accessible without proper authentication
  3. Check for plaintext credential storage
    Examine configuration files, backup files, or system logs for stored credentials. Look for any files containing passwords, account credentials, or authentication tokens in plaintext or weakly encoded formats.
    Affected if Sensitive credentials are stored in plaintext or easily reversible encoding within accessible configuration files
  4. Verify local access controls
    Review device access controls and permissions. Check if local interfaces (USB ports, SD card slots, debug ports) are properly secured and if the web management interface is accessible only to authorized users.
    Affected if Local access to sensitive configuration areas is not restricted or authenticated

A user is affected if their Tenda CP3 firmware is exactly version 11.10.00.2311090948 AND the password component or configuration files are accessible without proper authorization.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Limit physical and local network access to the device; contact Tenda for firmware updates; if no patch available, consider network segmentation and monitoring for unauthorized local access.

Fix this in Cp3 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
16.0 hours of engineering $2,800
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,480.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-24488 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-24488 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data