CVE-2024-25957
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedDell Grab for Windows, versions 5.0.4 and below, contains a cleartext storage of sensitive information vulnerability in its appsync module. An authenticated local attacker could potentially exploit this vulnerability, leading to information disclosure that could be used to access the appsync application with elevated privileges.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceDell Grab for Windows stores sensitive information in cleartext within its appsync module. An authenticated local attacker with access to the system can read this unencrypted sensitive data and use it to gain elevated privileges when accessing the appsync application.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 5.0.5CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check Dell Grab versionOpen Windows Settings > Apps > Apps & features, find Dell Grab, and note the version number. Alternatively, check the program files directory where Dell Grab is installed for a version file or use 'Get-ItemProperty' in PowerShell on the Dell Grab installation directory.Affected if The installed version is lower than 5.0.5 (e.g., 5.0.0, 4.x, etc.)
-
Locate the appsync module directoryNavigate to the Dell Grab installation directory (typically C:\Program Files\Dell\Dell Grab or C:\Program Files (x86)\Dell\Dell Grab) and search for a folder or file named 'appsync', 'appsync module', or similar.Affected if The appsync module directory or component exists in the Dell Grab installation folder
-
Inspect appsync files for cleartext credentialsWithin the appsync directory (if found), examine configuration files, database files, XML files, or any data storage files for usernames, passwords, API keys, tokens, or other sensitive credentials stored in plain, unencrypted text.Affected if Any file within the appsync module contains sensitive information (passwords, API keys, tokens, secrets) in cleartext readable format without encryption
-
Check for sensitive data in app configurationLook for configuration files such as config.xml, settings.ini, database.db, or similar in the Dell Grab installation or user data directories. Open these files with a text editor and search for patterns resembling passwords or keys.Affected if Configuration files contain plaintext sensitive data such as passwords, credentials, or cryptographic keys
A user is affected if Dell Grab version is below 5.0.5 AND the appsync module contains any cleartext sensitive information (passwords, credentials, tokens, or secrets) that could be exploited by a local authenticated attacker for privilege escalation.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped5.0.5
Implement proper encryption for sensitive information stored by the appsync module. Replace any cleartext storage mechanisms with secure encryption using appropriate cryptographic algorithms and key management.
5.0.5 or later
- Download Dell Grab for Windows version 5.0.5 or later from the official Dell support website
- Ensure you have administrative privileges on the local system
- Back up any existing Dell Grab configuration data if needed
- Uninstall the current version of Dell Grab for Windows
- Install the new version (5.0.5 or later) using the downloaded installer
- Verify the installation completed successfully
- Restart the system if prompted by the installer
- Confirm the appsync module no longer stores sensitive information in cleartext logs
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-25957 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-25957 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data