NVD · uneditedPDF-XChange Editor EMF File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of PDF-XChange Editor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of EMF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-22280.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThis is an out-of-bounds read vulnerability in PDF-XChange Editor's EMF (Enhanced Metafile) file parser. The lack of proper validation of user-supplied data during EMF file parsing allows reading past the end of an allocated buffer, leading to information disclosure. While the primary impact is sensitive information exposure, the vendor advisory notes this can be chained with other vulnerabilities to achieve arbitrary code execution.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 10.1.1.381= 10.1.1.381CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify installed PDF-XChange productsCheck Programs and Features (Windows) or the application's Help > About dialog for PDF-XChange Editor and PDF-XChange PDF ToolsAffected if Either product is present on the system
-
Determine PDF-XChange Editor versionIn the application, go to Help > About to view the exact version number, or locate the version in the installed program entryAffected if Version is exactly 10.1.1.381
-
Determine PDF-XChange PDF Tools versionCheck the installed version through Programs and Features or by locating the PDF-Tools component version informationAffected if Version is exactly 10.1.1.381
-
Confirm EMF file processing usageDetermine if the system or users open or process EMF (Enhanced Metafile) files through PDF-XChange productsAffected if EMF files are processed and the affected version is installed
You are affected if PDF-XChange Editor or PDF-XChange PDF Tools version 10.1.1.381 is installed and the system processes EMF files, as the vulnerability lies in the EMF parser component.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor-supplied patches for PDF-XChange Editor when available. Until then, instruct users to avoid opening untrusted EMF files or visiting untrusted webpages that could deliver malicious EMF content.
- Consultation3.0 h
- Implementation2.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,832.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-27328 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-27328 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm