CVE-2024-32741
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceSIMATIC CN 4100 devices contain a hardcoded default password hash used for both the privileged root user and the GRUB bootloader. An attacker who obtains and cracks this password hash can gain full root access to the device, compromising the entire system.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 3.0CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check the installed firmware versionAccess the device web interface or use Siemens management tools (e.g., TIA Portal, Web Navigator) to retrieve the firmware version. Alternatively, check via command line using 'plctool' or the device's diagnostic interface if available.Affected if The firmware version is lower than 3.0 (e.g., 2.x.x or any version < 3.0)
-
Verify if default root password is still in useAttempt to access the device via SSH or serial console using the default root credentials. The hardcoded hash corresponds to a default password that should have been changed. If login succeeds with factory-default credentials, the device is vulnerable.Affected if Default root password has not been changed from the factory default
-
Verify if default GRUB bootloader password is in useReboot the device and access the GRUB bootloader menu. Attempt to enter boot parameters or recovery mode. If the default GRUB password (derived from the hardcoded hash) is accepted, the device is vulnerable.Affected if Default GRUB password has not been changed from the factory default
-
Check for password hash files on device filesystemIf you have filesystem access (e.g., via firmware extraction or debugging interface), inspect /etc/shadow or equivalent password hash files for the root account. Look for the specific hardcoded hash value associated with this CVE.Affected if The hardcoded password hash is present in /etc/shadow or similar credential storage files
The device is affected if it runs firmware version earlier than 3.0, or if the default root or GRUB passwords have not been changed from the factory defaults.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped3.0
Update all affected devices to firmware V3.0 or later which removes the hardcoded credentials, and immediately change the default root and GRUB passwords on any deployed devices as an interim measure.
Firmware V3.0
- Obtain the V3.0 firmware update for SIMATIC CN 4100 from the official Siemens support portal (cert-portal.siemens.com or siemens.com/productsupport)
- Review the firmware upgrade instructions in the SIMATIC CN 4100 operating manual
- Upload and apply the V3.0 firmware to the device using the method specified in the documentation (typically via web-based management, TIA Portal, or SD card)
- After upgrade, verify the firmware version is V3.0 or higher
- Change the default root password immediately after upgrade to a strong, unique password
- If GRUB password was using the hardcoded default, reconfigure GRUB with a new secure password
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation8.0 h
- Implementation16.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $10,240.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-32741 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-32741 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data