Simatic Rf360r FirmwareOperating system · Siemens

CVE-2024-37991

MEDIUM · 6.5 CVSS v3.1 Published 2024-09-10
Fix available
A fix is available. Upgrade to 1.1 / 2.2 or later.
See remediation →
72/100
Remediation priority · Elevated
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Multiple Siemens SIMATIC RFID reader devices contain a vulnerability where service log files can be accessed without proper authentication. An unauthenticated attacker with network access could retrieve sensitive information from these exposed log files.

MitigationUpdate the affected devices to the specified fixed versions (V4.2 for RF610R/RF615R/RF650R/RF680R/RF685R models; V1.1 for RF1140R/RF1170R; V2.2 for RF166C/RF185C/RF186C/RF186CI/RF188C/RF188CI/RF360R) as listed in the Siemens advisory.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Simatic Rf360r FirmwareOperating system
Affected:< 2.2
Simatic Rf1170r FirmwareOperating system
Affected:< 1.1
Simatic Rf1140r FirmwareOperating system
Affected:< 1.1
Simatic Reader Rf685r Fcc FirmwareOperating system
Affected:< 4.2
Simatic Reader Rf685r Etsi FirmwareOperating system
Affected:< 4.2
Simatic Reader Rf685r Cmiit FirmwareOperating system
Affected:< 4.2
Simatic Reader Rf685r Arib FirmwareOperating system
Affected:< 4.2
Simatic Reader Rf680r Fcc FirmwareOperating system
Affected:< 4.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the RFID reader model
    Locate the device physically or check network inventory for the SIMATIC RFID reader model number (e.g., RF360R, RF1170R, RF1140R, RF680R, RF685R)
    Affected if The model is one of: RF360R, RF1170R, RF1140R, RF680R, or RF685R (any variant)
  2. Determine the installed firmware version
    Access the device web interface or use the device's management console to view the firmware version information
    Affected if The firmware version is lower than the affected threshold for that model (RF360R < 2.2, RF1170R < 1.1, RF1140R < 1.1, RF680R < 4.2, RF685R < 4.2)
  3. Verify network accessibility
    Confirm the device is reachable on the network from an untrusted segment or external network
    Affected if The device is accessible from a network segment where unauthenticated attackers could reach it
  4. Check for exposed log file paths
    Attempt to access common log file URLs or paths on the device web interface (e.g., /logs/, /service/logs/, or similar paths) without authentication
    Affected if Log files are returned without requiring authentication credentials

A user is affected if they have a SIMATIC RFID reader (RF360R, RF1170R, RF1140R, RF680R, or RF685R) running firmware below the fixed version threshold AND the device is network-accessible to unauthenticated attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 1.1 / 2.2 / 4.2 or later
Fixed in 1.12.24.2
Interim mitigation

Update the affected devices to the specified fixed versions (V4.2 for RF610R/RF615R/RF650R/RF680R/RF685R models; V1.1 for RF1140R/RF1170R; V2.2 for RF166C/RF185C/RF186C/RF186CI/RF188C/RF188CI/RF360R) as listed in the Siemens advisory.

Recommended fix High confidence

Upgrade to firmware version V2.2 for RF360R/RF166C/RF185C/RF186C/RF186CI/RF188C/RF188CI; V1.1 for RF1140R/RF1170R; V4.2 for all RF610R/RF615R/RF650R/RF680R/RF685R readers

  1. 1. Identify the exact model number and current firmware version of the affected SIMATIC RFID device from the Siemens product list.
  2. 2. Download the latest firmware update from Siemens Industry Online Support (support.industry.siemens.com) or the cert-portal.siemens.com reference.
  3. 3. Review the firmware release notes to confirm the version includes the CVE-2024-37991 security fix.
  4. 4. Follow Siemens standard firmware update procedures for the specific device (typically via TIA Portal, Web Based Management, or PC-based update tool).
  5. 5. After upgrading, verify that the service log files are no longer accessible without authentication.
  6. 6. Confirm the device is running the minimum fixed version: RF360R: V2.2, RF1140R: V1.1, RF1170R: V1.1, RF680R/RF685R: V4.2, and other listed readers: V4.2.
Caveat Review Siemens firmware release notes for any functional changes; firmware updates may require device reconfiguration or compatibility checks with connected systems

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Simatic Rf360r Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-37991 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-37991 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data