CVE-2024-38309
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThere are multiple stack-based buffer overflow vulnerabilities in V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceMultiple stack-based buffer overflow vulnerabilities exist in the file parsing components of V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier). Opening a specially crafted malicious file allows an attacker to overflow stack buffers, potentially achieving information disclosure and arbitrary code execution.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- None
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check if V-SFT is installedLocate the V-SFT application on the system and determine its installed version numberAffected if V-SFT version 6.2.2.0 or earlier is installed
-
Check if TELLUS is installedLocate the TELLUS application on the system and determine its installed version numberAffected if TELLUS version 4.0.19.0 or earlier is installed
-
Check if TELLUS Lite is installedLocate the TELLUS Lite application on the system and determine its installed version numberAffected if TELLUS Lite version 4.0.19.0 or earlier is installed
-
Compare installed versions to affected rangesCompare each found installation version against the affected version thresholds: V-SFT (6.2.2.0 and earlier), TELLUS (4.0.19.0 and earlier), TELLUS Lite (4.0.19.0 and earlier)Affected if Any installed version falls at or below the specified threshold for its product
If any of the three products (V-SFT, TELLUS, or TELLUS Lite) are installed at versions at or below the affected thresholds, the environment is vulnerable to the file parsing buffer overflow.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataDo not open untrusted or specially crafted files in affected software until vendor patches are released; implement proper bounds checking in file parsing routines.
- Consultation2.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,480.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-38309 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-38309 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data