7kt Pac1260 Data Manager FirmwareOperating system · Siemens

CVE-2024-41788

HIGH · 7.2 CVSS v3.1 Published 2025-04-08
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
78/100
Remediation priority · High
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Authenticated command injection vulnerability in the SENTRON 7KT PAC1260 Data Manager web interface. Specific GET request parameters lack input sanitization, allowing an authenticated attacker to inject arbitrary commands that execute with root privileges on the underlying Linux/system.

MitigationRestrict network access to the web interface to trusted IPs only and enforce strong authentication credentials until a vendor patch is available. Consider network segmentation to isolate the industrial device.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
7kt Pac1260 Data Manager FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Siemens 7KT PAC1260 Data Manager in your environment
    Locate the physical industrial device or inventory system and confirm presence of Siemens 7KT PAC1260 Data Manager hardware. Check network scanning results for devices identifying as this model.
    Affected if The device exists in your environment and is network-connected
  2. Confirm web interface is accessible
    Attempt to reach the device web interface via HTTP/HTTPS on the expected management port (commonly 80/443 or vendor-default). Use a browser or curl to verify the login page loads.
    Affected if The web interface responds and presents an authentication login page
  3. Verify authentication method and credential strength
    Review authentication logs or attempt login with any default or known credentials. Check if multi-factor authentication is enforced and if password complexity meets industrial security standards.
    Affected if The web interface uses weak, default, or easily guessable credentials, or lacks multi-factor authentication
  4. Assess network exposure of the web interface
    Review firewall rules, access control lists, and network segmentation to determine if the web management interface is reachable from untrusted network segments or the internet.
    Affected if The web interface is accessible from untrusted networks or outside the trusted IP range defined in your security policy

You are affected if the Siemens 7KT PAC1260 Data Manager is present in your environment and its web interface is accessible to attackers with network access, regardless of authentication status since the flaw requires only authenticated access.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict network access to the web interface to trusted IPs only and enforce strong authentication credentials until a vendor patch is available. Consider network segmentation to isolate the industrial device.

Fix this in 7kt Pac1260 Data Manager Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA3.0 h
21.0 hours of engineering $3,680
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,888.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-41788 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-41788 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data