CVE-2024-43653
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedImproper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceIocharger AC model firmware before version 24120701 contains an OS command injection vulnerability in an undocumented binary. An authenticated attacker with low-privilege access can inject arbitrary OS commands via crafted HTTP requests and execute them with root privileges, achieving full compromise of the charging station.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device model is Iocharger ACAccess the charger web interface or physical device label to identify the exact model. Iocharger AC is the affected product line.Affected if Device is not an Iocharger AC model charger
-
Check installed firmware versionLog into the web interface and navigate to System Settings, Device Info, or About page to view the firmware version number. Compare against the fixed version 24120701.Affected if Firmware version is below 24120701 (any version older than December 7, 2024)
-
Verify web interface accessibilityDetermine if the charger web management interface is exposed to untrusted networks or the internet. Check router/firewall port forwarding rules and network segmentation.Affected if Web interface is accessible from untrusted network segments or directly internet-facing
-
Audit user accountsAccess the user management section of the web interface to list all accounts. Note if any accounts with limited or guest-level privileges exist.Affected if Low-privilege or guest user accounts are configured on the device
Device is affected if it is an Iocharger AC model with firmware version lower than 24120701 and has low-privilege accounts or exposed web interface, allowing authenticated command injection.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade Iocharger AC charger firmware to version 24120701 or later to remediate this vulnerability. Prioritize devices exposed to untrusted networks given the critical impact and potential for network pivoting.
24120701
- Obtain the Iocharger firmware version 24120701 or later from the official vendor (iocharger.com)
- Verify the firmware integrity using checksums provided by the vendor
- Access the Iocharger AC charger administration interface
- Navigate to the firmware update section
- Upload and install firmware version 24120701 or later
- Verify the firmware was applied successfully
- Confirm the web interface is functioning normally after the update
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-43653 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-43653 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data