CWE-27Weakness · CWE-27

CVE-2024-43658

HIGH · 7.2 CVSS v4.0 Published 2025-01-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
78/100
Remediation priority · High
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A path traversal vulnerability in the Iocharger Home web interface allows authenticated users to delete arbitrary files on the device by manipulating file paths in HTTP requests. The vulnerability affects AC model firmware before version 25010801 and can be exploited over the network without requiring elevated privileges or user interaction.

MitigationUpgrade Iocharger AC model firmware to version 25010801 or later to remediate the path traversal vulnerability. Restrict network access to the charging station web UI as an interim control.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
Authentication
Y
User interaction
None
Scope
N

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:X/V:X/RE:X/U:X

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Iocharger AC model device
    Identify if the target device is an Iocharger AC model charging station by checking the device label, admin UI header, or SNMP/sysinfo output for 'Iocharger' and 'AC' model identifiers
    Affected if Device is not an Iocharger AC model - the CVE does not apply
  2. Check installed firmware version
    Log into the Iocharger Home web interface and locate the firmware version in the system settings or status page, or query the device's /api/system/info endpoint if available
    Affected if Firmware version is before 25010801 (e.g., 24091200, 24060101, etc.)
  3. Verify web interface is exposed
    Attempt to reach the Iocharger web UI via HTTP/HTTPS on the device's IP address (common ports 80/443 or configured port)
    Affected if Web interface is reachable from network and firmware version is below 25010801 - exploitation is possible
  4. Confirm authentication is in use
    Verify that the web interface requires login credentials (check if unauthenticated access to protected pages redirects to login)
    Affected if Attacker has valid credentials AND web interface is accessible AND firmware is below 25010801 - conditions for exploitation are met

A user is affected if they have an Iocharger AC model device running firmware version below 25010801 with the web interface accessible on the network.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade Iocharger AC model firmware to version 25010801 or later to remediate the path traversal vulnerability. Restrict network access to the charging station web UI as an interim control.

Recommended fix Moderate confidence

firmware version 25010801 or later

  1. Identify the specific Iocharger AC model charging station device on the network
  2. Access the device's web interface using authenticated credentials
  3. Navigate to the firmware settings or system update section
  4. Check the current firmware version under the device settings or status page
  5. Download firmware version 25010801 or later from the official Iocharger website (iocharger.com) or vendor support portal
  6. In the web interface, locate the firmware upload/update function
  7. Upload the downloaded firmware file (version 25010801 or later)
  8. Wait for the firmware upload and installation process to complete - do not power off the device during this process

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing4.0 h
  • Review / QA2.0 h
16.0 hours of engineering $2,840
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,544.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-43658 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-43658 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data