CWE-256Weakness · CWE-256

CVE-2024-43659

HIGH · 7.2 CVSS v3.1 Published 2025-01-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
78/100
Remediation priority · High
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Iocharger AC model EV chargers running firmware versions before 25010801 contain hardcoded default credentials stored in a configuration file accessible via firmware extraction or after exploiting a separate code execution/file inclusion vulnerability. These credentials provide superuser access to the web interface, enabling arbitrary command execution through the System → Custom page.

MitigationUpdate Iocharger AC chargers to firmware version 25010801 or later, which enforces mandatory password change on first login. For devices running older firmware, manually change the default password immediately.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the firmware version
    Access the device admin interface or check the firmware version via the device's built-in diagnostics or version display. This is typically found in the System Info or About page of the web interface.
    Affected if The firmware version is any version number lower than 25010801 (for example, 24091201, 24060101, etc.)
  2. Verify if default credentials are still active
    Attempt to log into the web interface using the known hardcoded default credentials. These credentials are stored in a configuration file on the device.
    Affected if The default credentials (username and password) successfully grant superuser access to the web interface, indicating the hardcoded credentials have not been changed.
  3. Confirm web interface access with superuser privileges
    After logging in with default credentials, navigate to the System → Custom page.
    Affected if The page is accessible and allows command execution, confirming the attacker can execute arbitrary commands through this feature.
  4. Check for evidence of credential persistence
    If you have file system access (via firmware extraction or a separate vulnerability), examine the configuration file where the hardcoded credentials are stored.
    Affected if The hardcoded default credentials are present in the configuration file and have not been replaced with a unique user-defined password.

The device is affected if it runs firmware version 25010801 or earlier and the hardcoded default credentials are still active, allowing unauthorized superuser access to the web interface.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update Iocharger AC chargers to firmware version 25010801 or later, which enforces mandatory password change on first login. For devices running older firmware, manually change the default password immediately.

Recommended fix High confidence

Firmware version 25010801 or later for Iocharger AC model EV chargers

  1. Identify the Iocharger AC model charger and current firmware version via the web UI or system settings
  2. Download the latest firmware version 25010801 or later from the official Iocharger vendor website (iocharger.com) or authorized distribution channel
  3. Review the firmware upgrade instructions provided by the vendor to ensure proper procedure
  4. Perform the firmware upgrade following the vendor's recommended process
  5. After upgrading, on first login the system will require a mandatory password change - complete this immediately
  6. Set a unique, strong password that is different from any other devices
  7. Verify the upgrade was successful by checking the firmware version in the system information
  8. If available, enable any additional security settings recommended by the vendor
Caveat Review vendor release notes for any functional changes or configuration requirements in the new firmware version before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,690
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,304.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-43659 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-43659 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data