CWE-552Weakness · CWE-552

CVE-2024-43660

HIGH · 7.5 CVSS v3.1 Published 2025-01-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A path traversal vulnerability in the CGI script of Iocharger AC charger firmware allows authenticated users to download arbitrary files from the filesystem by manipulating file paths (e.g., ../../etc/shadow). The vulnerability requires authentication but no other preconditions, enabling full disclosure of sensitive files including credentials, source code, and configuration.

MitigationUpgrade Iocharger AC charger firmware to version 24120701 or later. If patching is not immediately possible, restrict network access to the web management interface to trusted networks only and rotate any credentials that may have been exposed.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Iocharger AC charger device
    Identify Iocharger AC charger on your network and verify it exposes a web-based management interface (CGI-based)
    Affected if Device is an Iocharger AC charger with an accessible web interface
  2. Check installed firmware version
    Access the device admin panel or system information page to retrieve the current firmware build number
    Affected if Firmware version is earlier than 24120701 (the patched release)
  3. Verify web interface authentication status
    Confirm whether the web management interface is accessible with valid credentials or uses default credentials
    Affected if Valid administrative credentials exist or are in use for the device web interface
  4. Test CGI script for path traversal
    If authenticated to the web interface, attempt to access a known CGI endpoint with a path traversal payload such as ../../etc/passwd or ../../etc/shadow
    Affected if The CGI script returns the contents of arbitrary files outside the web root directory

Device is affected if it is an Iocharger AC charger running firmware versions before 24120701 with an accessible web interface where valid credentials can be used to trigger the path traversal in the CGI script.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade Iocharger AC charger firmware to version 24120701 or later. If patching is not immediately possible, restrict network access to the web management interface to trusted networks only and rotate any credentials that may have been exposed.

Recommended fix High confidence

Iocharger AC model charger firmware version 24120701 or later

  1. Identify the current firmware version of the Iocharger AC model charger
  2. Download the firmware version 24120701 or later from the official Iocharger support channels
  3. Follow the vendor's standard firmware upgrade procedure to apply the update
  4. Verify the firmware was successfully updated by checking the version number
  5. Confirm the vulnerability is resolved by testing that the CGI script no longer allows arbitrary file downloads

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation3.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,130
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,408.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-43660 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-43660 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data