Progauge Maglink Lx Console FirmwareOperating system · Doverfuelingsolutions

CVE-2024-45373

HIGH · 8.8 CVSS v3.1 Published 2024-09-25
Fix available
A fix is available. Upgrade to after 4.17.9e or later.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Once logged in to ProGauge MAGLINK LX4 CONSOLE, a valid user can change their privileges to administrator.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

ProGauge MAGLINK LX4 CONSOLE allows any authenticated user to escalate their own privileges to administrator level by modifying their user account settings. This vertical privilege escalation occurs due to missing or inadequate server-side authorization controls on the privilege modification functionality.

MitigationImplement proper role-based access control (RBAC) on the server side to prevent non-administrator users from modifying their privilege level. Restrict privilege modification functionality to administrator accounts only and add validation checks before any privilege changes.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Progauge Maglink Lx Console FirmwareOperating system
Affected:<= 3.4.2.2.6
Progauge Maglink Lx4 Console FirmwareOperating system
Affected:<= 4.17.9e

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device firmware version
    Access the ProGauge MAGLINK LX or LX4 Console web interface and navigate to System Settings or About page to locate the firmware version. Alternatively, check the console's system information or diagnostics page.
    Affected if The firmware version is <= 3.4.2.2.6 for MAGLINK LX Console or <= 4.17.9e for MAGLINK LX4 Console
  2. Verify if user account management functionality exists
    Log into the console with a non-administrator user account and navigate to the User Account Settings or User Management section to see if privilege modification options are available.
    Affected if The interface allows authenticated users to access user account settings where privilege level can be modified
  3. Test privilege escalation capability
    Using a non-administrator authenticated account, attempt to modify your own user account settings to change the privilege level to Administrator.
    Affected if A non-administrator user can successfully elevate their own account privileges to administrator level
  4. Check for server-side authorization controls
    Inspect the application's user management API endpoints or configuration to verify if server-side role-based access control checks are performed before allowing privilege modifications.
    Affected if The system does not enforce server-side authorization checks to restrict privilege modification to administrator accounts only

A user is affected if the console firmware is at or below the affected version AND the system allows any authenticated non-administrator user to escalate their own privileges to administrator level through user account settings.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 4.17.9e
Interim mitigation

Implement proper role-based access control (RBAC) on the server side to prevent non-administrator users from modifying their privilege level. Restrict privilege modification functionality to administrator accounts only and add validation checks before any privilege changes.

Fix this in Progauge Maglink Lx Console Firmware Scoped from the published advisory
  • Consultation8.0 h
  • Implementation12.0 h
  • Testing6.0 h
  • Review / QA4.0 h
30.0 hours of engineering $5,380
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,608.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-45373 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-45373 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data