CWE-613Weakness · CWE-613

CVE-2024-45386

HIGH · 8.8 CVSS v3.1 Published 2025-02-11
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
95/100
Remediation priority · Urgent
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This is a session management vulnerability where affected Siemens industrial software products (SIMATIC PCS neo, SIMOCODE ES, SIRIUS Safety ES, SIRIUS Soft Starter ES, and TIA Administrator) fail to properly invalidate user sessions upon logout. An attacker who has obtained a valid session token through other means can continue using that session even after the legitimate user has logged out, effectively achieving unauthorized access.

MitigationApply vendor-supplied updates (V4.1 Update 2, V5.0 Update 1, V19 Update 1, TIA Administrator 3.0.4) to implement proper server-side session invalidation. As an interim measure, enforce short session timeouts and monitor for anomalous session reuse.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed Siemens industrial software
    Review installed programs or check installation directories for SIMATIC PCS neo, SIMOCODE ES, SIRIUS Safety ES, SIRIUS Soft Starter ES, or TIA Administrator
    Affected if Any of these products are installed on the system
  2. Determine product version
    Access the product's About or Help section, or check the installation folder for version information, then compare against the fixed versions (TIA Administrator before 3.0.4, SIMATIC PCS neo before V4.1 Update 2, SIMOCODE ES/SIRIUS Safety ES/SIRIUS Soft Starter ES before V5.0 Update 1 or V19 Update 1 depending on product line)
    Affected if Installed version is older than the vendor fixed versions
  3. Verify session timeout configuration
    Access the product's administrative or security settings and inspect the session timeout duration setting
    Affected if Session timeout is set to an extended period (hours) or is not explicitly configured, increasing the window for token reuse
  4. Test session invalidation behavior
    If test environment available, log in to the product, capture the session token, log out, then attempt to use the original token with an API call or re-authentication attempt
    Affected if The original session token remains valid after logout (server accepts it)

A user is affected if any of these Siemens products are installed with a version prior to the fixed releases and the session token remains valid after explicit logout.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor-supplied updates (V4.1 Update 2, V5.0 Update 1, V19 Update 1, TIA Administrator 3.0.4) to implement proper server-side session invalidation. As an interim measure, enforce short session timeouts and monitor for anomalous session reuse.

Recommended fix High confidence

Minimum fixed versions: SIMATIC PCS neo V4.1 Update 2, V5.0 Update 1; SIMOCODE ES V19 Update 1; SIRIUS Safety ES V19 Update 1; SIRIUS Soft Starter ES V19 Update 1; TIA Administrator V3.0.4

  1. Identify which affected Siemens products (SIMATIC PCS neo, SIMOCODE ES, SIRIUS Safety ES, SIRIUS Soft Starter ES, TIA Administrator) are deployed in your environment
  2. Download the appropriate update from Siemens Industry Online Support (support.industry.siemens.com) or your standard software distribution channel
  3. For SIMATIC PCS neo V4.1: upgrade to V4.1 Update 2 or later
  4. For SIMATIC PCS neo V5.0: upgrade to V5.0 Update 1 or later
  5. For SIMOCODE ES V19: upgrade to V19 Update 1 or later
  6. For SIRIUS Safety ES V19: upgrade to V19 Update 1 or later
  7. For SIRIUS Soft Starter ES V19: upgrade to V19 Update 1 or later
  8. For TIA Administrator: upgrade to V3.0.4 or later
Caveat Review Siemens release notes for each update for any compatibility or configuration changes before deploying to production

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation8.0 h
  • Implementation24.0 h
  • Testing16.0 h
  • Review / QA8.0 h
56.0 hours of engineering $9,760
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $15,616.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-45386 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-45386 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data