CVE-2024-51346
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn issue in Eufy Homebase 2 version 3.3.4.1h allows a local attacker to obtain sensitive information via the cryptographic scheme.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · low confidenceLocal privilege escalation or information disclosure vulnerability in Eufy Homebase 2's cryptographic implementation. The flaw allows a local attacker with access to the device or local network to obtain sensitive information, likely including credentials, encryption keys, or stored camera data, due to improper key management or weak cryptographic scheme.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm device model is Eufy Homebase 2Check the device label or access the Eufy app to verify the exact model number of your Homebase deviceAffected if The device is an Eufy Homebase 2 (any firmware version)
-
Identify installed firmware versionAccess the Eufy app settings, go to Homebase settings, and record the firmware version number shownAffected if Firmware version is older than the version containing the vendor fix (compare to Eufy's official security advisory)
-
Assess local network exposureCheck your router settings to determine if the Homebase device is accessible from outside your local network or has port forwarding enabled to itAffected if The device is exposed to the internet or accessible beyond your trusted local network
-
Review network services and open portsUse a network scanner from a device on the same network to check for open ports or unexpected services on the Homebase IP addressAffected if Unexpected open ports or services are listening on the Homebase device
-
Check for unauthorized access indicatorsReview the Eufy app event logs and any connected device lists for unfamiliar devices or unusual access timesAffected if Unknown devices have accessed the Homebase or unusual access patterns are logged
You are affected if you own an Eufy Homebase 2 with firmware older than the vendor's patched version, especially if the device is accessible beyond your local network.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware update when available; restrict physical and local network access to the Homebase device; monitor for unauthorized local access attempts.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-51346 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-51346 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data