Connext ProfessionalApplication · Rti

CVE-2024-52061

CRITICAL · 9.8 CVSS v3.1 Published 2024-12-13
Fix available
A fix is available. Upgrade to 5.3.1.45 / 6.0.1.40 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in RTI Connext Professional (Core Libraries, Queuing Service, Recording Service, Routing Service) allows Overflow Variables and Tags.This issue affects Connext Professional: from 7.4.0 before 7.5.0, from 7.0.0 before 7.3.0.5, from 6.1.0 before 6.1.2.21, from 6.0.0 before 6.0.1.40, from 5.0.0 before 5.3.1.45.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A classic buffer overflow vulnerability exists in RTI Connext Professional's Core Libraries, Queuing Service, Recording Service, and Routing Service. The flaw allows overflow of variables and tags due to insufficient bounds checking when copying data into fixed-size buffers. This critical flaw (CVSS 9.8) can potentially allow remote code execution or denial of service when processing malformed data.

MitigationUpgrade RTI Connext Professional to version 7.5.0, 7.3.0.5, 6.1.2.21, 6.0.1.40, or 5.3.1.45 or later. Apply network segmentation and input validation as temporary mitigations if immediate upgrade is not feasible.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Connext ProfessionalApplication
Affected:>= 5.0.0, < 5.3.1.45>= 6.0.0, < 6.0.1.40>= 6.1.0, < 6.1.2.21>= 7.0.0, < 7.3.0.5>= 7.4.0, < 7.5.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify RTI Connext Professional installation
    Locate the RTI Connext installation directory, typically under $RTI_HOME or C:\rti_connext. Check for the 'rti_connext_professional' folder or search for 'rtiddscore' libraries (rti_<os>_<arch>.dll on Windows, librti_<os>_*.so on Linux).
    Affected if RTI Connext Professional is installed on the system.
  2. Determine installed version
    Check the version file or product information. In the installation root, look for a version manifest, README, or execute 'rtiddsgen -version' if available. The version is often in the directory name (e.g., rti_connext_professional-7.3.0) or in a version.properties file.
    Affected if The installed version falls within any of these ranges: 5.0.0 to 5.3.1.44, 6.0.0 to 6.0.1.39, 6.1.0 to 6.1.2.20, 7.0.0 to 7.3.0.4, or 7.4.0 to 7.4.x.
  3. Confirm vulnerable components are in use
    Identify if any of these services are running or configured: Core Libraries (rti_<os>_<arch>.dll/lib), Queuing Service (rtiqueuingservice), Recording Service (rtirecordingservice), or Routing Service (rtiroutingservice). Check running processes or startup configurations for these executables.
    Affected if Any of the Core Libraries, Queuing Service, Recording Service, or Routing Service components are active.
  4. Check for exposed DDS interfaces
    Examine the domain participant configuration XML files (usually in <installation>/resource/xml/ or user-defined paths) for <domain_participant> elements. Identify if DDS ports (typically UDP/UDPv6 ports 7400-7403 for default domains) are accessible from untrusted networks using tools like netstat or by reviewing firewall rules.
    Affected if DDS domain participants are configured and accessible over the network.

The system is affected if RTI Connext Professional version is below 7.5.0 (or below 7.3.0.5, 6.1.2.21, 6.0.1.40, or 5.3.1.45 depending on the major branch) and any of the vulnerable components (Core Libraries, Queuing, Recording, or Routing Service) are in use.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 5.3.1.45 / 6.0.1.40 / 6.1.2.21 or later
Fixed in 5.3.1.456.0.1.406.1.2.21
Interim mitigation

Upgrade RTI Connext Professional to version 7.5.0, 7.3.0.5, 6.1.2.21, 6.0.1.40, or 5.3.1.45 or later. Apply network segmentation and input validation as temporary mitigations if immediate upgrade is not feasible.

Recommended fix High confidence

Upgrade to Connext Professional 5.3.1.45 (5.x), 6.0.1.40 (6.0.x), 6.1.2.21 (6.1.x), or 7.3.0.5 (7.x) or later - choose the appropriate minor version that contains the fix for your current branch

  1. 1. Identify the currently installed Connext Professional version by checking the installation directory or running the version command specific to your deployment
  2. 2. Determine which version branch you are currently on (5.x, 6.0.x, 6.1.x, or 7.x)
  3. 3. Download the appropriate fixed version from the RTI customer portal or official distribution channels: for 5.x branch upgrade to 5.3.1.45 or later; for 6.0.x upgrade to 6.0.1.40 or later; for 6.1.x upgrade to 6.1.2.21 or later; for 7.x upgrade to 7.3.0.5 or later
  4. 4. Review RTI Connext Professional release notes for the target version to understand any compatibility considerations
  5. 5. Back up all existing Connext configurations, XML files, and persistent data
  6. 6. Stop all running Connext services (Core Libraries, Queuing Service, Recording Service, Routing Service) before upgrading
  7. 7. Install the upgraded version following the standard RTI installation procedure
  8. 8. Restore configurations from backup after installation
Caveat Review release notes for compatibility notes between your current version and target version; major version jumps may require configuration adjustments or affect existing deployments

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Connext Professional Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing12.0 h
  • Review / QA4.0 h
28.0 hours of engineering $4,760
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,616.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-52061 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-52061 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data