CVE-2024-52334
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly. This could allow an attacker to recover the original passwords and might gain unauthorized access.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThe syngo.plaza VB30E application stores user passwords without proper encryption. An attacker with access to the password storage mechanism (e.g., database, configuration files) could recover plaintext passwords and use them for unauthorized access to the application.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the syngo.plaza version installedLocate the application version information in the system. This is typically found in the application metadata, About screen, or installation directory. Common locations include registry keys (on Windows), version files in the installation directory, or the application GUI under Help > About.Affected if The installed version is syngo.plaza VB30E and the version is earlier than VB30E_HF07 (or HF07 is not listed in the version string).
-
Locate password storage locationsIdentify where the application stores user credentials. Check the application database (commonly SQL-based, check for tables named like Users, Credentials, Auth, or similar), and configuration files in the installation directory that may contain password data.Affected if Password storage locations exist and are accessible to the user performing this check.
-
Inspect stored password formatQuery the user/password storage location and examine the stored password values. If using a database: SELECT username, password FROM <user_table>. If in config files: open the relevant configuration file and locate password fields.Affected if Passwords appear as plaintext (directly readable alphanumeric strings), or use weak encoding (like Base64) without cryptographic hashing. Properly fixed versions should show encrypted or hashed values that are not directly reversible to plaintext.
-
Verify encryption mechanism on password fieldsIf passwords appear obfuscated, determine the encryption or hashing method used. Check application documentation, configuration settings, or code references for the encryption algorithm. Common weak methods include simple encoding (Base64, hex) or reversible encryption with static keys.Affected if No proper cryptographic protection is found - passwords use encoding only (Base64, hex), symmetric encryption with hardcoded keys, or no protection at all.
-
Assess access controls on password storageReview file system permissions on password storage files and database access controls. Determine what user accounts can read the password data.Affected if The account performing this check, or other non-privileged accounts, can access and read the password storage without special administrative privileges.
You are affected if the installed syngo.plaza version is VB30E before HF07 and stored passwords can be read in plaintext or easily reversible format from accessible storage locations.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade to syngo.plaza VB30E_HF07 or later which contains proper password encryption. If immediate patching is not possible, implement additional access controls on password storage locations and monitor for unauthorized access attempts.
VB30E_HF07
- 1. Identify the current installed version of syngo.plaza VB30E by checking the application or system information
- 2. Verify the current version is earlier than VB30E_HF07 (vulnerable versions)
- 3. Obtain the VB30E_HF07 or later release from Siemens Healthineers official channels
- 4. Schedule a maintenance window for the upgrade procedure
- 5. Perform a complete backup of the current system configuration and database
- 6. Apply the upgrade to VB30E_HF07 following Siemens Healthineers installation documentation
- 7. Verify the upgrade was successful and the application is functioning correctly
- 8. Confirm the password encryption vulnerability is resolved by reviewing release notes or consulting vendor
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation6.0 h
- Implementation12.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,968.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-52334 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-52334 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data