Tecnomatix Plant SimulationApplication · Siemens

CVE-2024-52569

HIGH · 7.8 CVSS v3.1 Published 2024-11-18
Fix available
A fix is available. Upgrade to 2302.0018 / 2404.0007 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24260)

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Out-of-bounds write vulnerability in Teamcenter Visualization and Tecnomatix Plant Simulation when parsing specially crafted WRL (VRML) files, allowing code execution in the context of the current process.

MitigationApply vendor patches: update Teamcenter Visualization to V14.2.0.14/V14.3.0.12/V2312.0008/V2406.0005 or later, and Tecnomatix Plant Simulation to V2302.0018/V2404.0007 or later.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Tecnomatix Plant SimulationApplication
Affected:< 2302.0018>= 2404.0, < 2404.0007

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed product
    Check if Siemens Tecnomatix Plant Simulation or Teamcenter Visualization is installed on the system. Look for installation directories (typically under C:\Program Files\Siemens or C:\Program Files (x86)\Siemens) or check installed programs in Windows Programs and Features.
    Affected if Neither product is installed (not affected). Either product is installed, proceed to version check.
  2. Check Tecnomatix Plant Simulation version
    Open Tecnomatix Plant Simulation, go to Help > About, or check the installed version in Windows Programs and Features. Note the full version number including all four digit groups (e.g., 2302.0018).
    Affected if Version is less than 2302.0018 OR version is 2404.0 through 2404.0006 (inclusive). Both conditions indicate vulnerability.
  3. Check Teamcenter Visualization version
    Open Teamcenter Visualization, check Help > About, or locate the version in the installation directory. Record the full version string (e.g., V14.2.0.14).
    Affected if Version is earlier than V14.2.0.14, V14.3.0.12, V2312.0008, or V2406.0005. Any of these indicate vulnerability.
  4. Verify WRL file parsing capability
    Check if the application has WRL (VRML) file import or viewer functionality enabled. Look for WRL file handlers in the application or file type associations. This is the attack vector: the vulnerability triggers when parsing specially crafted WRL files.
    Affected if WRL file parsing feature is present and enabled. The vulnerability only applies when this feature can process malicious WRL files.

User is affected if either Tecnomatix Plant Simulation version is < 2302.0018 or between 2404.0-2404.0006, or Teamcenter Visualization version is earlier than the fixed releases, AND the WRL/VRML file parsing feature is available in the installation.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 2302.0018 / 2404.0007 or later
Fixed in 2302.00182404.0007
Interim mitigation

Apply vendor patches: update Teamcenter Visualization to V14.2.0.14/V14.3.0.12/V2312.0008/V2406.0005 or later, and Tecnomatix Plant Simulation to V2302.0018/V2404.0007 or later.

Recommended fix High confidence

Tecnomatix Plant Simulation V2302.0018 (for V2302 line) or V2404.0007 (for V2404 line)

  1. 1. Identify the currently installed Tecnomatix Plant Simulation version (V2302 or V2404 series)
  2. 2. For V2302.x users: Upgrade to version V2302.0018 or later
  3. 3. For V2404.x users: Upgrade to version V2404.0007 or later
  4. 4. Obtain the update from official Siemens channels (Siemens Support or Software Lifecycle Management)
  5. 5. Before deployment, validate the new version in a test environment
  6. 6. After upgrade, verify that WRL file parsing functionality works correctly
Caveat Review Siemens release notes for associated changes; minor version updates typically have low risk but validate custom configurations

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Tecnomatix Plant Simulation Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA2.0 h
11.0 hours of engineering $1,930
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,088.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-52569 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-52569 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data