D View 8Application · Dlink

CVE-2024-5298

HIGH · 8.8 CVSS v3.0 Published 2024-05-23
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
94/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the queryDeviceCustomMonitorResult method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21842.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

D-Link D-View contains a remote code execution vulnerability in the queryDeviceCustomMonitorResult method. This method is exposed as a dangerous functionality that allows authenticated attackers (or those who bypass authentication) to execute arbitrary code with root privileges on the affected system.

MitigationApply available vendor patches from D-Link; if no patch exists, implement network segmentation to isolate the D-View service and monitor for indicators of compromise.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
D View 8Application
Affected:= 2.0.1.28

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm D-Link D-View installation
    Locate D-Link D-View installation directory or check running processes for D-View components. Common paths may include C:\Program Files\D-Link\D-View or /opt/dview on Linux systems.
    Affected if D-Link D-View software is found running on the system
  2. Identify installed version
    Check the D-View application version through its about dialog, installation directory files, or system registry entries. Look for version 2.0.1.28 specifically.
    Affected if Installed version matches exactly 2.0.1.28 of D-View 8
  3. Verify network accessibility of D-View service
    Determine if the D-View web interface or API endpoints are exposed on network ports. Check firewall rules and listening services on common ports (typically 80, 443, or custom ports).
    Affected if D-View service is accessible from network and accepts requests
  4. Check for the vulnerable queryDeviceCustomMonitorResult endpoint
    Inspect web server configuration or attempt to access the queryDeviceCustomMonitorResult API method through HTTP requests if the service is exposed. This method should not be publicly accessible.
    Affected if The queryDeviceCustomMonitorResult method is exposed and reachable without additional security controls

User is affected if D-Link D-View version 2.0.1.28 is installed and the queryDeviceCustomMonitorResult method is network-accessible with insufficient access controls.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply available vendor patches from D-Link; if no patch exists, implement network segmentation to isolate the D-View service and monitor for indicators of compromise.

Fix this in D View 8 Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing10.0 h
  • Review / QA5.0 h
33.0 hours of engineering $5,760
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $9,216.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-5298 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-5298 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data