CVE-2024-55407
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn issue in the DeviceloControl function of ITE Tech. Inc ITE IO Access v1.0.0.0 allows attackers to perform arbitrary port read and write actions via supplying crafted IOCTL requests.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA vulnerability in the DeviceIoControl function of ITE Tech Inc ITE IO Access driver v1.0.0.0 allows unvalidated IOCTL requests to trigger arbitrary I/O port read and write operations, potentially enabling an attacker to interact with hardware ports at will.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm ITE IO Access driver presenceOpen Device Manager, expand 'System devices' or search for 'ITE IO Access' driver. Alternatively, run 'driverquery /v | findstr -i ITE' or check for the driver file (typically iteioaccess.sys or similar) in C:\Windows\System32\driversAffected if The ITE IO Access driver is installed on the system
-
Retrieve driver file versionRight-click the driver file in C:\Windows\System32\drivers (or the identified driver file), select Properties, then go to the Details tab and view Product Version. Alternatively, use PowerShell: Get-ItemProperty 'C:\Windows\System32\drivers\drivername.sys' | Select-Object VersionInfoAffected if The driver version is 1.0.0.0 or matches the affected version range
-
Verify driver is accessible to untrusted callersCheck driver permissions by examining the security descriptor: use 'sc sdshow drivername' or check ACLs in Device Manager driver properties under the Security tab. Verify non-admin users or low-privilege processes can send IOCTL requestsAffected if Non-privileged users or processes can access the driver's DeviceIoControl interface
-
Identify exposed IOCTL interfaceRun 'winobj' or use 'NtObjectManager' to locate the device object (typically \Device\ITEIOAccess or \??\ITEIOAccess) and enumerate granted access masks. Check if the device accepts arbitrary IOCTL codesAffected if The driver device object accepts IOCTL requests without validation checks
-
Monitor for suspicious IOCTL activityEnable Kernel API hooking or use ETW tracing (Microsoft-Windows-Kernel-API) to log DeviceIoControl calls to the ITE driver. Look for IOCTL codes performing port read/write operations (typically IOCTL_ITE_*) with unexpected parametersAffected if IOCTL requests targeting I/O ports are being processed without documented validation
A system is affected if the ITE IO Access driver version 1.0.0.0 is present and its DeviceIoControl interface is accessible to callers who can send unvalidated IOCTL requests for arbitrary I/O port operations.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor-provided patches for the ITE IO Access driver; if no patch exists, implement input validation and whitelist-based access controls within the driver's IOCTL handler to restrict port access to legitimate requests only.
- Consultation4.0 h
- Implementation16.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,960.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-55407 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-55407 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data