CVE-2024-56181
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to alter the secure boot configuration without proper authorization by directly communicate with the flash controller.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe vulnerability allows authenticated attackers to directly communicate with the flash controller on affected SIMATIC IPC devices, bypassing protection mechanisms for EFI (Extensible Firmware Interface) variables. This enables unauthorized modification of secure boot configuration, potentially allowing malicious code execution at firmware level.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelLocate the device model information via system inventory, device label, or management interface. SIMATIC IPC devices are industrial PCs from Siemens.Affected if The device is a SIMATIC IPC model
-
Determine the firmware versionAccess the device firmware/EFI setup (typically via BIOS key during boot) or use Siemens-provided system management tools to query the current firmware version.Affected if The installed firmware version matches or falls within the affected version range for this CVE
-
Verify flash controller access controlsReview device security configuration settings or system management interface to determine if the flash controller interface has unrestricted or inadequately protected access.Affected if The flash controller interface is accessible without proper authentication or protection mechanisms
-
Inspect EFI variable protection statusCheck EFI/BIOS configuration for the status of variable protection mechanisms. This may be visible in secure boot settings or flash controller protection options.Affected if EFI variable protection mechanisms are disabled, missing, or can be bypassed
-
Confirm secure boot configurationExamine the secure boot setting in the EFI/BIOS. Secure boot should be enabled to protect against unauthorized firmware modifications.Affected if Secure boot is disabled or misconfigured, allowing potential modification of secure boot variables
A user is affected if they have a SIMATIC IPC device with a vulnerable firmware version and the flash controller or EFI variable protection is accessible or misconfigured.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedApply vendor-provided firmware updates (specific versions listed in CVE) to affected devices. Restrict physical and administrative access to the flash controller interface to prevent unauthorized EFI variable manipulation.
Install device-specific firmware: BX-21A to V31.01.07; BX-32A/BX-39A/PX-32A/PX-39A/PX-39A PRO to V29.01.07; BX-59A to V32.01.04; RC-543A to V36.01.03; RC-543B to V35.01.12; RW-543A to V1.1.4; RW-543B to V35.02.10; IPC127E to V27.01.11; IPC227G/IPC277G/IPC277G PRO/IPC327G/IPC377G to V28.01.14; IPC627
- 1. Identify the exact SIMATIC IPC model number from the affected device list
- 2. Check the current firmware version installed on the device
- 3. For devices with available fixes (BX-21A, BX-32A, BX-39A, BX-59A, PX-32A, PX-39A, PX-39A PRO, RC-543A, RC-543B, RW-543A, RW-543B, IPC127E, IPC227G, IPC277G, IPC277G PRO, IPC327G, IPC377G, IPC627E, IPC647E, IPC677E, IPC847E): Download and install the corresponding firmware update from Siemens support portal (cert-portal.siemens.com)
- 4. For devices listed as 'All versions' without fixed versions (Field PG M5, IPC227E, IPC3000 SMART V3, IPC277E, IPC347G, IPC427E, IPC477E, IPC477E PRO, IPC527G, ITP1000): Contact Siemens ProductCERT for firmware updates or remediation guidance
- 5. After applying firmware updates, verify the EFI variable protection is functioning by confirming secure boot configuration cannot be altered without proper authorization
- 6. If no firmware update is available, implement network segmentation and restrict physical access to the device to mitigate the attack vector
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation8.0 h
- Implementation16.0 h
- Testing12.0 h
- Review / QA8.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $12,352.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2024-56181 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2024-56181 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data