CWE-693Weakness · CWE-693

CVE-2024-56182

HIGH · 8.2 CVSS v3.1 Published 2025-03-11
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to disable the BIOS password without proper authorization by directly communicate with the flash controller.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This vulnerability exists in the EFI (Extensible Firmware Interface) variable storage mechanism of multiple SIMATIC industrial PCs. An authenticated attacker can directly communicate with the flash controller to manipulate EFI variables, allowing them to disable BIOS password protection without proper authorization. This bypasses the intended security control at the firmware level.

MitigationApply the vendor-supplied firmware updates to the specific patched versions indicated for each affected model. Verify that EFI variable protections are properly enabled after updating, and review administrative access controls to limit exposure to authenticated attackers.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify device model and platform
    Check if the system is a SIMATIC industrial PC or Field PG device by reviewing system information, device labels, or using commands like 'dmidecode -s system-product-name' or 'Get-WmiObject Win32_ComputerSystem' in PowerShell
    Affected if Device is a SIMATIC IPC or Field PG model
  2. Check installed firmware version
    Access the BIOS/UEFI setup or use vendor tools to retrieve the current firmware version. On Windows, check via 'msinfo32' or vendor-specific utilities. Compare against fixed versions: Field PG M6 should be below V26.01.12, IPC BX-21A should be below V31.01.07
    Affected if Firmware version is lower than the fixed version for your specific model
  3. Verify EFI variable access controls
    Check if the system allows direct communication with the flash controller by examining UEFI/BIOS settings for 'Secure Boot' status and any 'Flash/BIOS write protection' settings. On Linux, inspect 'efivar -l' to list accessible EFI variables
    Affected if Secure Boot is disabled or EFI variables are writable by the OS
  4. Confirm BIOS password protection status
    Enter BIOS/UEFI setup (typically via F2 or Del on boot) and verify if a BIOS admin password is set. Check if the password can be bypassed or if the option to disable password authentication is exposed
    Affected if No BIOS password is set, or password protection settings show as disabled or modifiable without authentication

You are affected if your device is a SIMATIC IPC or Field PG with firmware version below the fixed release for your model and EFI variable storage is accessible or unprotected.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-supplied firmware updates to the specific patched versions indicated for each affected model. Verify that EFI variable protections are properly enabled after updating, and review administrative access controls to limit exposure to authenticated attackers.

Recommended fix High confidence

Firmware version meeting or exceeding the threshold versions specified in Siemens Security Advisory (e.g., V26.01.12, V28.01.14, V25.02.15, etc. depending on model)

  1. 1. Identify the exact model and current firmware version of the affected SIMATIC IPC device using the device's system information or Siemens tooling.
  2. 2. Consult the Siemens product security advisory on cert-portal.siemens.com for the specific patch/revision corresponding to your device model.
  3. 3. Download the recommended firmware update from the official Siemens support website (support.industry.siemens.com) ensuring the version matches or exceeds: Field PG M6: V26.01.12, IPC BX-21A: V31.01.07, IPC BX-32A/BX-39A: V29.01.07, IPC BX-59A: V32.01.04, IPC PX-32A/PX-39A/PX-39A PRO: V29.01.07, IPC RC-543A: V36.01.03, IPC RC-543B: V35.01.12, IPC RW-543A: V1.1.4, IPC RW-543B: V35.02.10, IPC127E:
  4. 4. Create a full backup of the current device configuration and firmware before proceeding.
  5. 5. Apply the firmware update following the official Siemens flashing procedure documented in the device manual - typically via USB bootable recovery media or Siemens-provided update utility.
  6. 6. After update completion, verify the new firmware version is correctly installed and confirm the EFI variable protection is active.
  7. 7. For devices with 'All versions' affected and no version listed (e.g., IPC227E, IPC277E, IPC347G, IPC427E, IPC477E, IPC477E PRO, IPC527G, Field PG M5, IPC3000 SMART V3), contact Siemens directly for available mitigations or firmware updates.
Caveat Firmware updates may require device downtime and could reset certain BIOS/UEFI settings; ensure backup of configuration before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation8.0 h
  • Implementation16.0 h
  • Testing12.0 h
  • Review / QA8.0 h
44.0 hours of engineering $7,720
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $12,352.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-56182 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-56182 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data