Hard-coded CredentialsWeakness · CWE-798

CVE-2024-8893

HIGH · 7.3 CVSS v3.1 Published 2025-02-14
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
82/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The GoodWe GW1500-XS solar inverter firmware version 1.1.2.1 contains hard-coded credentials embedded in the firmware that allow unauthorized Wi-Fi access from physical proximity. An attacker within Wi-Fi range can use these static credentials to authenticate to the inverter's web interface without any user interaction or knowledge.

MitigationContact GoodWe for a firmware update that removes hardcoded credentials and implements proper authentication. As a compensating control, isolate the inverter on a restricted network VLAN and disable Wi-Fi if not operationally required.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm inverter model
    Access the inverter's web interface or check the device label/monitoring app to verify the model number is GW1500-XS
    Affected if Model is not GW1500-XS (different models may have different firmware and may not be affected)
  2. Check installed firmware version
    Log into the inverter's web interface and navigate to the system information or firmware version page; alternatively check via the GoodWe monitoring app or serial console
    Affected if Firmware version is 1.1.2.1 (this is the only version explicitly listed as affected)
  3. Verify Wi-Fi is enabled
    Access the inverter's network or wireless settings page in the web interface, or check the physical LED status indicators on the device
    Affected if Wi-Fi is enabled - the vulnerability requires the attacker to be within Wi-Fi range to use the hardcoded credentials

User is affected only if the inverter is a GW1500-XS running firmware version 1.1.2.1 with Wi-Fi functionality enabled

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Contact GoodWe for a firmware update that removes hardcoded credentials and implements proper authentication. As a compensating control, isolate the inverter on a restricted network VLAN and disable Wi-Fi if not operationally required.

Have this fixed Scoped from the published advisory
  • Consultation4.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
15.0 hours of engineering $2,690
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,304.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2024-8893 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2024-8893 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data