CVE-2025-0128
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA denial-of-service (DoS) vulnerability in the Simple Certificate Enrollment Protocol (SCEP) authentication feature of Palo Alto Networks PAN-OS® software enables an unauthenticated attacker to initiate system reboots using a maliciously crafted packet. Repeated attempts to initiate a reboot causes the firewall to enter maintenance mode. Cloud NGFW is not affected by this vulnerability. Prisma® Access software is proactively patched and protected from this issue.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA denial-of-service vulnerability exists in the SCEP authentication feature of PAN-OS that allows unauthenticated attackers to trigger system reboots using maliciously crafted packets. Repeated exploitation causes the firewall to enter maintenance mode, resulting in extended service disruption.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- Y
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Amber
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify PAN-OS versionRun 'show system info' in the PAN-OS CLI or check the dashboard in the web interface to obtain the installed software version.Affected if The installed version is within a known vulnerable version range for CVE-2025-0128.
-
Verify SCEP service statusIn the PAN-OS web interface, navigate to Device > Server Profiles > SCEP or use 'show scep' command in CLI to check if any SCEP profile is configured.Affected if One or more SCEP profiles exist and the SCEP service is active.
-
Inspect SCEP CSRAgent configurationReview the SCEP profile settings to confirm the Certificate Signing Request (CSR) enrollment feature is enabled; check Device > Certificate Management > SCEP.Affected if The CSRAgent or SCEP enrollment functionality is enabled in any profile.
-
Review system logs for SCEP-related errorsRun 'show log system' with filter for 'scep' or 'SCEP' events, particularly look for crash, reboot, or authentication failure entries around suspected attack times.Affected if Logs show repeated SCEP authentication failures or unexpected system restarts correlated with SCEP activity.
The environment is affected if the PAN-OS version is vulnerable AND SCEP is enabled with an active SCEP profile, as this provides the attack surface for unauthenticated attackers to trigger reboots.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply available PAN-OS patches for CVE-2025-0128; if SCEP is not required in the environment, consider disabling the SCEP service to reduce attack surface.
- Consultation4.0 h
- Implementation3.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,440.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-0128 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-0128 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm