CVE-2025-10538
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn authentication bypass vulnerability exists in LG Innotek camera models LND7210 and LNV7210R. The vulnerability allows a malicious actor to gain access to camera information including user account information.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceLG Innotek camera models LND7210 and LNV7210R contain an authentication bypass vulnerability that allows unauthenticated attackers to bypass authentication mechanisms and access sensitive camera information, including user account credentials.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the camera modelCheck the device web interface, physical label, or SNMP enumeration for the exact model number. Look for LND7210 or LNV7210R designations.Affected if The camera model is LG Innotek LND7210 or LNV7210R
-
Verify authentication is requiredAttempt to access the camera web interface or API endpoints without providing credentials. Check if authentication is properly enforced on protected pages such as /settings, /config, or /admin areas.Affected if Authentication can be bypassed and sensitive pages are accessible without credentials
-
Check for credential exposure endpointsInspect camera API endpoints or configuration pages for exposure of user account credentials, password hashes, or authentication tokens. Common paths may include user management or system info pages.Affected if User credentials or authentication tokens are visible without authentication
-
Assess network exposureDetermine if the camera is directly accessible from untrusted networks. Review firewall rules, NAT configurations, and network segmentation policies affecting the device.Affected if The camera is accessible from untrusted networks without network-level access controls
A user is affected if they have an LG Innotek LND7210 or LNV7210R camera where authentication can be bypassed to access sensitive credential information, especially if the device is network-accessible from untrusted networks.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware updates when available; until then, restrict network exposure of affected cameras using network segmentation and firewall rules, and monitor for unauthorized access attempts.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-10538 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-10538 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data