CVE-2025-11500
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedTinycontrol devices such as tcPDU and LAN Controllers LK3.5, LK3.9 and LK4 have two separate authentication mechanisms - one solely for interface management and one for protecting all other server resources. When the latter is turned off (which is a default setting), an unauthenticated attacker on the local network can obtain usernames and encoded passwords for interface management portal by inspecting the HTTP response of the server when visiting the login page, which contains a JSON file with these details. Both normal and admin users credentials are exposed. This issue has been fixed in firmware versions: 1.36 (for tcPDU), 1.67 (for LK3.5 - hardware versions: 3.5, 3.6, 3.7 and 3.8), 1.75 (for LK3.9 - hardware version 3.9) and 1.38 (for LK4 - hardware version 4.0).
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceTinycontrol devices (tcPDU, LAN Controllers LK3.5/3.9/4) have a default setting that exposes usernames and encoded passwords in a JSON file within the HTTP login page response when the secondary authentication mechanism is disabled. An unauthenticated attacker on the local network can retrieve these credentials via HTTP response inspection.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Adjacent
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the device's web interface or check the device label/documentation to confirm it is a Tinycontrol tcPDU, LAN Controller LK3.5, LK3.9, or LK4Affected if The device is not one of these models, the CVE does not apply
-
Check the firmware versionLocate the firmware version in the device web interface (usually under System > Status or Settings > About) or via the device's APIAffected if The installed version is below 1.36 for tcPDU, below 1.67 for LK3.5, below 1.75 for LK3.9, or below 1.38 for LK4 (compare to the fixed versions)
-
Verify secondary authentication statusIn the device web interface, navigate to Security or Authentication settings and check whether the secondary authentication mechanism is enabled or disabledAffected if Secondary authentication is disabled, the credentials are exposed in the login page response
-
Inspect HTTP login page responseUsing a browser developer tool or curl, perform a GET request to the device login page and examine the response body for a JSON structure containing usernames and encoded passwords (e.g., look for JSON keys like 'users', 'passwords', 'credentials', or similar)Affected if The HTTP response contains a JSON object with plaintext usernames or encoded password data that should not be visible to unauthenticated users
A user is affected if they have a Tinycontrol tcPDU, LK3.5, LK3.9, or LK4 device with firmware below the fixed versions AND secondary authentication is disabled, resulting in exposed credentials in the login page response.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpdate firmware to versions 1.36 (tcPDU), 1.67 (LK3.5), 1.75 (LK3.9), or 1.38 (LK4) and rotate exposed passwords as a precautionary measure. Ensure the secondary authentication mechanism is properly configured after update.
tcPDU: firmware 1.36 | LK3.5: firmware 1.67 | LK3.9: firmware 1.75 | LK4: firmware 1.38
- 1. Identify the Tinycontrol device model (tcPDU, LK3.5, LK3.9, or LK4) and hardware version
- 2. Download the appropriate firmware update from the official Tinycontrol vendor website: https://tinycontrol.pl
- 3. For tcPDU: upgrade to firmware version 1.36
- 4. For LK3.5 (hardware versions 3.5, 3.6, 3.7, 3.8): upgrade to firmware version 1.67
- 5. For LK3.9 (hardware version 3.9): upgrade to firmware version 1.75
- 6. For LK4 (hardware version 4.0): upgrade to firmware version 1.38
- 7. After upgrading, verify that the secondary authentication mechanism is properly configured and the login page no longer exposes credentials in the HTTP response
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation3.0 h
- Implementation6.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,984.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-11500 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-11500 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data