CVE-2025-11545
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedExposure of Sensitive System Information to an Unauthorized Control Sphere vulnerability in Sharp Display Solutions projectors allows a attacker may improperly access the HTTP server and execute arbitrary actions.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceSharp Display Solutions projectors contain an HTTP server vulnerability allowing unauthenticated attackers to improperly access the server and execute arbitrary actions. This critical flaw (CVSS 9.5) exposes sensitive system information to unauthorized parties and potentially enables remote code execution on the affected device.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the projector interface or check the device label to confirm it is a Sharp Display Solutions projector. Note the exact model number for version verification.Affected if The device is a Sharp Display Solutions projector and the firmware version falls within any affected ranges (compare your installed version to the affected ranges if known).
-
Verify HTTP server statusAccess the projector's web-based management interface or check the network configuration menu to determine if the built-in HTTP server is enabled.Affected if The HTTP server feature is enabled and accessible on the device.
-
Check HTTP server network exposureScan the network to determine if the projector's HTTP port (typically port 80/443) is exposed to untrusted networks or the internet. Use a network scan or review firewall rules.Affected if The HTTP server is reachable from untrusted network segments or external IP addresses without authentication barriers.
-
Inspect for unauthorized access indicatorsReview any available logs on the projector's web interface or connected management systems for unusual HTTP requests, unknown IP addresses, or unexpected configuration changes.Affected if Logs show HTTP requests from unauthorized sources or suspicious activity patterns indicating potential exploitation.
A user is affected if they have a Sharp Display Solutions projector with HTTP server enabled and exposed to untrusted networks, regardless of whether exploitation indicators are present.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor-supplied firmware patches when available; if no patch exists, restrict network access to projectors via firewall rules or place them in isolated network segments to limit exposure to unauthorized users.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-11545 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-11545 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data