CVE-2025-11694
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA security issue exists within 1769 CompactLogix controllers due to the missing validation of sequence numbers and source IP addresses in the CIP protocol. This allows attacker to abuse the exposed Connection ID’s visible on the web interface to perform denial-of-service attacks, resulting in a minor fault.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThe vulnerability exists in 1769 CompactLogix controllers where the CIP (Common Industrial Protocol) implementation lacks validation of sequence numbers and source IP addresses. Attackers can observe exposed Connection IDs via the web interface and craft malicious CIP messages that cause denial-of-service conditions resulting in minor controller faults.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the controller modelAccess the controller's web interface or use RSLinx Classic to browse the network and confirm the device is a 1769 CompactLogix controller. Check the controller's firmware version through the web interface or Studio 5000 Logix Designer.Affected if The device is a 1769 CompactLogix controller of any firmware version (no specific version range provided for comparison).
-
Verify web interface accessibilityAttempt to access the controller's built-in web server by navigating to the controller's IP address in a web browser. Check if the web interface responds and displays the Connection IDs or status page.Affected if The web interface is accessible from the network, exposing Connection IDs that attackers can observe.
-
Assess network exposureReview the network configuration to determine if the controller's IP address is reachable from untrusted networks. Check firewall rules, VLAN configuration, and router access control lists surrounding the controller.Affected if The controller is on an exposed network segment without proper network segmentation or firewall protection.
-
Check CIP communication statusVerify that CIP (Common Industrial Protocol) communications are enabled on the controller. This is typically always enabled by default on CompactLogix controllers. Use Wireshark or a network analyzer on the same network segment to capture CIP traffic.Affected if CIP communications are enabled and reachable, allowing attackers to craft malicious CIP messages.
A user is affected if they have a 1769 CompactLogix controller with an accessible web interface on a network where untrusted parties can send CIP messages, as the lack of sequence number and source IP validation enables DoS attacks via crafted CIP messages.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImplement network segmentation to restrict unauthorized access to the controller, apply compensating controls such as firewalls, and contact Rockwell Automation for firmware updates that properly validate CIP sequence numbers and source IP addresses.
- Consultation8.0 h
- Implementation12.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $9,088.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-11694 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-11694 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data