CVE-2025-12097
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThere is a relative path traversal vulnerability in the NI System Web Server that may result in information disclosure. Successful exploitation requires an attacker to send a specially crafted request to the NI System Web Server, allowing the attacker to read arbitrary files. This vulnerability existed in the NI System Web Server 2012 and prior versions. It was fixed in 2013.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA relative path traversal vulnerability in the NI System Web Server allows attackers to craft specially crafted HTTP requests containing relative path sequences (e.g., ../) to access files outside the web root directory, resulting in information disclosure of arbitrary system files.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm NI System Web Server is installedCheck for the presence of NI software directories (typically under C:\Program Files\National Instruments\ or C:\ProgramData\National Instruments) or look for 'NI System Web Server' in Windows Services or installed programs list.Affected if The NI System Web Server software is present on the system.
-
Identify the NI System Web Server versionCheck the version of the NI System Web Server by inspecting the executable or service properties. Common paths include the NI installation directories. Compare the version number against known releases from before and after 2013.Affected if The installed version was released prior to 2013, as the fix was included in 2013 releases.
-
Verify the web server service is runningOpen Windows Services (services.msc) and look for 'NI System Web Server' or check via command: sc query NISystemWebServer or netstat -an | findstr :80 to identify if HTTP service is active.Affected if The NI System Web Server service is running and accepting HTTP connections.
-
Test for path traversal accessibilityIf the web server is accessible (e.g., http://localhost or reachable IP), attempt a controlled test request using relative path sequences such as GET /../../windows/win.ini or similar safe test to observe if arbitrary file access is possible.Affected if The server returns content from files outside the web root directory, indicating the path traversal vulnerability is exploitable.
-
Review network exposure of the web serverCheck firewall rules and network configuration to determine if the web server HTTP port (typically 80/443) is exposed to untrusted networks. Use netstat -an or firewall snap-in to list listening ports and associated IP bindings.Affected if The NI System Web Server is bound to 0.0.0.0 or an exposed network interface and is accessible from untrusted networks.
You are affected if the NI System Web Server is installed, runs a version released before 2013, and is accessible either locally or over the network, as the path traversal vulnerability allows reading arbitrary files outside the web root.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade the NI System Web Server to a version released after 2013, which contains the fix. If immediate upgrade is not feasible, restrict network access to the web server via firewall rules and implement web application firewall (WAF) protections.
NI System Web Server 2013 or later
- 1. Identify the current version of NI System Web Server installed on the system
- 2. If the version is NI System Web Server 2012 or earlier, plan an upgrade to a 2013 or later version
- 3. Before upgrading, backup all existing configurations and data
- 4. Obtain the NI System Web Server 2013 or later installer from the official NI website (www.ni.com)
- 5. Install the newer version following NI's standard installation procedures
- 6. After installation, verify the web server is operational and test that the path traversal vulnerability is no longer present
- 7. Reconfigure any custom settings from the backup as needed
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation4.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,968.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-12097 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-12097 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data