CVE-2025-12592
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedLegacy Vivotek Device firmware uses default credetials for the root and user login accounts.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceLegacy Vivotek device firmware ships with hardcoded default credentials for both root and user login accounts, allowing remote attackers to gain full administrative access to affected devices.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- Y
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:Red
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify Vivotek devices on the networkUse network scanning tools (such as Nmap, Angry IP Scanner, or asset discovery) to locate devices with Vivotek vendor signatures in MAC OUI (00:0E:2A, 00:1B:2B, 00:25:3F) or HTTP headers/HTML title containing 'Vivotek' or recognizable Vivotek product modelsAffected if Any Vivotek device is found on the network without documented remediation
-
Determine device firmware versionAccess the device web interface (http[s]://<device-ip>) and navigate to System > System Info or System > Maintenance > Firmware Upgrade, or use SNMP queries (snmpwalk -v2c -c <community> <device-ip> .1.3.6.1.4.1.22010.3.1.1.2) to retrieve the firmware version stringAffected if Firmware version matches legacy Vivotek firmware builds known to ship with hardcoded credentials (typically pre-2018 releases) or cannot be determined because the device responds with default credential prompts
-
Verify default credentials are still activeAttempt to authenticate to the device web interface or telnet/SSH service using known default credential pairs for Vivotek devices: root/root, root/admin, user/user, user/admin, or admin/admin. Document whether login succeeds without password change promptsAffected if Any default credential pair successfully authenticates or the device accepts login without enforcing immediate password change on first access
-
Check remote administrative access configurationReview the device network settings via its web interface (Network > General > HTTP/HTTPS ports, Network > Remote Access) or query SNMP OIDs .1.3.6.1.4.1.22010.3.2.1.1.1 (HTTP enable) and .1.3.6.1.4.1.22010.3.2.1.1.2 (HTTPS enable) to determine if remote HTTP/HTTPS administrative interfaces are enabledAffected if Remote HTTP or HTTPS administrative access is enabled on WAN-facing interfaces or untrusted network segments
-
Review authentication logs for exploitation signsAccess device logs via System > Log > Access Log or syslog exports and search for successful root/user logins from unfamiliar IP addresses, multiple authentication attempts, or account changes that do not correlate with documented administrative activityAffected if Logs show successful administrative logins from unknown source IPs or patterns consistent with brute-force or credential stuffing attacks
The environment is affected if any Vivotek device with legacy firmware retains default credentials in active use or exposes administrative interfaces remotely without credential changes.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImmediately change default credentials on all affected devices to unique, strong passwords; disable remote administrative access if not required; network segment affected devices; check for firmware updates from vendor.
- Consultation4.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-12592 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-12592 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm