CVE-2025-13510
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedThe Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThe Iskra iHUB and iHUB Lite smart metering gateways have their web management interface exposed without any authentication requirement. This allows any unauthenticated remote attacker to access the administrative interface and modify critical device settings including meter configurations, network parameters, and potentially billing data.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- Authentication
- X
- User interaction
- None
- Scope
- X
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelAccess the device web interface or check physical labels to confirm the device is an Iskra iHUB or iHUB Lite smart metering gateway. Look for iHUB branding on the device or in the web interface header.Affected if The device is an Iskra iHUB or iHUB Lite model.
-
Verify web interface accessibilityAttempt to access the device web management interface via HTTP (port 80) or HTTPS (port 443) from a browser. Do not enter any credentials when prompted.Affected if The web interface loads and displays device pages without requiring any login credentials.
-
Check for unauthenticated access to settingsNavigate to device configuration sections such as meter settings, data export parameters, or network settings within the web interface without logging in.Affected if You can view and modify critical settings including meter configuration and data export parameters without authentication.
-
Confirm network exposureDetermine if the device web interface is accessible from untrusted networks by testing access from outside the expected management network segment.Affected if The device web management interface is reachable from networks outside the trusted management zone.
A user is affected if they have an Iskra iHUB or iHUB Lite device whose web management interface is accessible and allows access to configuration settings without any authentication credentials.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImmediately restrict network access to the device management interfaces via firewall rules or network segmentation. Apply any vendor-provided firmware updates that implement authentication. If no patch is available, consider replacing affected devices with hardened alternatives.
- Consultation8.0 h
- Implementation16.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $10,240.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-13510 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-13510 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data