Pdf ArchitectApplication · Pdfforge

CVE-2025-14419

HIGH · 7.8 CVSS v3.0 Published 2025-12-23
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
pdfforge PDF Architect PDF File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of pdfforge PDF Architect. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-27902.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

This vulnerability in pdfforge PDF Architect stems from improper validation of user-supplied data during PDF file parsing, leading to memory corruption. An attacker can exploit this by crafting a malicious PDF file that, when opened by a victim, allows arbitrary code execution in the context of the current process. User interaction is required (opening a malicious file or visiting a malicious page).

MitigationAvoid opening PDF files from untrusted sources and refrain from visiting untrusted websites until an official vendor patch is available. Organizations should consider implementing additional email gateway filtering for PDF attachments and network-level protections.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Pdf ArchitectApplication
Affected:= 9.1.74.23030

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm PDF Architect installation
    Check for PDF Architect in the Windows registry under HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall or look in Program Files for a PDF Architect folder
    Affected if PDF Architect is not found on the system, the vulnerability does not apply
  2. Locate the executable and retrieve version
    Navigate to the PDF Architect installation directory (typically C:\Program Files\PDF Architect or C:\Program Files (x86)\PDF Architect) and locate the main executable, then right-click to view Properties > Details for the File Version
    Affected if Cannot locate the executable indicates the product may not be installed or is installed in a non-standard location
  3. Compare installed version to affected version
    Compare the File Version shown (for example 9.1.74.23030) to the affected version 9.1.74.23030. The '=' in the affected range indicates exactly this version is vulnerable
    Affected if The installed version exactly matches 9.1.74.23030 and the user opens a malicious PDF file

A user is affected only if PDF Architect version 9.1.74.23030 is installed AND a malicious PDF file is opened by that user.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Avoid opening PDF files from untrusted sources and refrain from visiting untrusted websites until an official vendor patch is available. Organizations should consider implementing additional email gateway filtering for PDF attachments and network-level protections.

Fix this in Pdf Architect Scoped from the published advisory
  • Consultation4.0 h
  • Implementation16.0 h
  • Testing12.0 h
  • Review / QA4.0 h
36.0 hours of engineering $6,200
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $9,920.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-14419 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-14419 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data